P a g e
|
15
P4 shows Pre-Heat Settings
Enable Pre-Heat
– True
Pre-Heat Time
– 10
Crank Time
– 3
Figure 6
The feed speed can be
adjusted to suit the
material being chipped see
Figure 6. Turn dial to align
number with pip. Set feed
speed so that the No-
Stress operates as
little as possible, this will
give the highest
throughput. When feeding
Leylandii or leafy material,
set feed roller speed to 4.5.
Emergency Stopping
– Standard Programme
To stop engine turn off with
ignition key by turning fully
anticlockwise.
1 CONTROL VALVE FEED SPEED
ADJUSTMENT.
POSITION INDICATED BY PIP.
0 = MINIMUM
10 = MAXIMUM
Feed
speed
adjustment
Summary of Contents for TR6
Page 5: ...P a g e 4 ...