background image

Overview ColostroMAT 

1

 

2

 

3

 

5

 

4

 

6

 

1 Control unit box  
2 Control 
3 Lid  
4 Water tank 
5 ColostroBAG-storage 
6 Handle 

3

 

2

 

1

 

4

 

5

 

6

 

7

 

1 Control unit box  
2 Main switch 
3 Power connection 
4 Service door 
5 Cold water supply 
6 Warm water connection 
7 Water drain 

Summary of Contents for ColostroMAT

Page 1: ...ColostroMAT Förster Technik GmbH 40FIT Schulung KW 20 2016 Jürgen Plesse ...

Page 2: ...2 3 5 4 6 1 Control unit box 2 Control 3 Lid 4 Water tank 5 ColostroBAG storage 6 Handle 3 2 1 4 5 6 7 1 Control unit box 2 Main switch 3 Power connection 4 Service door 5 Cold water supply 6 Warm water connection 7 Water drain ...

Page 3: ...Overview ColostroMAT 3 1 2 1 Bag holder 2 Bax fixer ...

Page 4: ...Profile 1 Profile 2 Profile 3 Profile 4 Main menu Control Operating unit ColostroMAT 4 ...

Page 5: ...dicator 5 Example Display indicator main menu Example Display indicator Profile 1 Operating mode main menu 2 Temperature 3 Time 4 main menu 1 Operating mode Profile 1 2 Temperature 3 Time 4 Condition of Profile 1 ...

Page 6: ... 1 Cold water supply 2 Warm water supply 3 waste water Installation ColostroMAT Even ground Connect water supply Water hose to cold water Water hose to warm water if needed Drain hose to the outflow and into the gully ...

Page 7: ...Commissioning Connect power plug and turn on via main switch When switching on the first time select water supply via Cold water supply Warm and cold water supply Set time Select hours an minutes via 7 ...

Page 8: ...sabled by default Waiting mode device doesn t perform any function Function mode a profile is running There is a difference made between two operating modi Basic mode Expert mode Press while starting with the main switch While holding in the left of the display is shown 8 ...

Page 9: ... Basic mode limited changes in the settings possible Mail menu Drain valve Start cleaning Time Operating modi 9 ...

Page 10: ...e Main menu Drain valve Start cleaning Time Diagnosis Water supply settings Cleaning settings Time settings Drain valve settings Contrast settings Standby settings Temperature unit Profil settings Factory settings Informations Operating modi 10 ...

Page 11: ... for 60 minutes After that it s cooled down to 42 C With profil 2 the water bath is heated up and following hold on 60 C for 60 minutes After that it s cooled down With profil 3 the water bath is heated up to 42 C With profil 4 the water bath is completely emptied and filled with cold water 11 ...

Page 12: ...Profile process Profile 1 12 Place ColostroBAGs in the bag holder Fix ColostroBAGs Pusch and start profile with Enter ...

Page 13: ...ofile 3 Place ColostroBAGs in the bag holder Fix ColostroBAGs Push Select temperature of the ColostroBAGs Room temperature Cooled Frozen only appears if there was something set in the expert mode Start profile with Enter ...

Page 14: ...ost rinsing Procedure of the cleaning 1 Place detergent reservoire in the rotating cage 2 Fill detergent in the reservoire 3 Switch into the cleaning menu via 4 Confirm with Enter to start the cleaning 5 The cleaning starts and all LEDs over the profile buttons blink Cleaning 14 ...

Page 15: ...desired temperature in the standby via Select start of the standby phase via Select end of the standby phase via Select start of the standby phase 2 via Select end of the standby phase 2 via Note If there are two overlapping standby phases the one which lasts longer obtains Set standby time 15 ...

Page 16: ...the expert mode Selection of the pasteurisation time via confirm with Enter Selection of the pasteurisation temperature via confirm with Enter Selection of the feeding temperature via confirm with Enter Selection of the time to the end of the profile via confirm with Enter 16 ...

Page 17: ...Warnings error messages 17 Lack of water Drain valve Heating Sensor ...

Page 18: ...sert SD cart in the provided Slot on the board Insert power plug and switch on the ColostroMAT Wait until the update is performed and confirm with Enter Turn off the ColostroMAT and remove the power plug Remove SD cart Close control unit box Insert power plug and switch on the ColostroMAT 18 ...

Page 19: ...ColostroFIT the Solution 19 ...

Page 20: ... Spindle Colostrometer or refractometer Min 50 g IgG l Ensure quality ...

Page 21: ...Pasteurization 21 Pasteurization 60 ºC for 60 min Carefully in a water bath Use ColostroBAGs ...

Page 22: ... can be kept up to 7 days1 In the freezer 20 ºC the colostrum can be kept for up to a year1 Long term storage after pasteurization in cases where no colostrum is available from the mother cow 1 Calf Rearing Guide Practical and easy to use S J Charlton CONTEXT ...

Page 23: ...Rewarm 23 Rewarm to 40 ºC to the optimal feed temperature Use ColostroBAG 1 COLOSTRUM Pasteurizing Guidelines Sam Leadley Calf Heifer Management Specialist Attica Vet Assoc 2013 ...

Page 24: ...ooner after birth 6 hours after birth the absorbtion rate has decreased by half Colostrum Feeding Checklist Sam Leadley Calf Heifer Management Specialist Attica Vet Assoc 2013 Tube calves only if necessary get instruction from veterinarian ...

Page 25: ... ColostroMAT pasteurization and heating gentle heating in a water bath easy to set up intuitive operation clear structured and safe work flow ColostroFIT the solution ...

Page 26: ...bles to easily and gently fill up pasteurize store defrost the colostrum for the new born calf For Feeding the colostrum to the calf a teat or tube can fast and easy be connected to the ColostroBAG ColostroFIT the solution ...

Page 27: ...27 ColostroMAT ColostroKIT BagFiller Caddy Colostrometer ColostroFIT scope of delivery ...

Page 28: ...28 ColostroKIT 50x ColostroBAGs 3x Tubes 3x Teats 1x TeatFix ColostroFIT scope of delivery ...

Page 29: ...ColostroFIT scope of delivery ColostroKIT small 10x ColostroBAGs 1x Tubes 1x Teats ...

Page 30: ...d products supplied or names may differ from those illustrated Although the contents of this presentation have been compiled with the greatest possible care Förster Technik cannot accept liability for any damage that might arise from errors or omissions in this presentation 30 ...