110
Failures and warnings
•
The mixer is evacuated.
3. Check the mixer drain valve if your automatic feeder has one.
•
Confirm the
Mixer emptying warning
by choosing
.
•
Confirm
Mixer drain: open?
by choosing
.
•
The mixer is evacuated.
4. Check the bar electrode.
•
Visually check the bar electrode for deposits.
5. Fill and drain the mixer.
•
Confirm the
Mixer emptying warning
by choosing
.
6. Confirm
Water bo. start?
by choosing
.
•
The mixer fills up with water.
7. Confirm
Mixer: drain?
by choosing
.
The mixer is drained.
Once the failure is eliminated, the message
Delete failure?
appears in the display. Confirm
Delete failure?
by choosing
.
If this does not correct the error, you must contact a service technician immediately.
7.2.3
Temperature sensor, mixer
The
Temp. sensor, mixer warning
is shown in the display if the temperature sensor in the
mixer jar is defective or the temperature of the mixed feed in the mixer jar drops below 0 °C.
You must contact a service technician immediately.
7.2.4
Unknown transmitters
The
Unknown transmitters warning
appears in your display:
•
If a transmitter is detected by the identification unit for which no animal number has been
assigned.
•
If a transmitter number has been allocated to an animal number, but has still not been reg-
istered.
Summary of Contents for TAP5-CH2-25
Page 2: ......
Page 6: ...6 Table of contents ...
Page 102: ...102 Running the automatic feeder ...
Page 119: ...Appendix 119 9 Appendix 9 1 Feeding 9 1 1 Standard feeding plans 9 1 1 1 Group A ...
Page 120: ...120 Appendix 9 1 1 2 Group B 9 1 1 3 Group C ...
Page 121: ...Appendix 121 9 1 1 4 Group D ...
Page 122: ...122 Appendix 9 1 1 5 Template for individual feeding plan ...
Page 123: ...Appendix 123 9 1 2 Basic principle of interval feeding ...