5
TECHNICAL
SPECIFICATION
Technical data
Power supply
2500 VA
Battery voltage
24 VDC
Charging current
20 A
Charging voltage
27,6V +/- 0,5V
AC voltage range
150 ~ 270 VAC
Output voltage range
AVR: 230 / 110V VAC +/- 8% ;
Batteries: 230 / 110V VAC +/-1%
(depending on version)
Inverter output frequency
50 Hz +/- 0.5 Hz
Overload protection
Battery mode: when the 110%~130%
overload mode is activated, the
device can still work for 30 seconds
then turn off the device; when the
130% and above overload mode is
activated, immediately disconnect
the device from the external power
source and turn off the device.
Network mode: overload warning
Temperature range
0~40 C
Humidity range
10%RH~90%RH
Operating noise level
71 dB
Weight
85 kg
Technical data is shown on the nameplate mounted on the rear panel of the
housing. Always quote the serial number on the rating plate when contacting the
service department.
Fortador Europe
Manufacturer:
Model:
230V AC 50-60 Hz
Voltage (IN):
230V AC+-1%(ACU)+-8%AVR
Voltage (OUT):
2500 VA /1800 W / <1A
Power:
2x100Ah VRLA AGM
Battery:
24V DC
Batery Voltage:
85kg
Weight:
V010011
S/N:
2021
Manufacturing year:
Fortador Power Bank V-Series
Read the instructions carefully before use! Made in Poland