6.  While your PC remains connected, cycle power on the Integrity system frame and 

wait patiently for the system to reset and reload all settings.  This will take several 
minutes and varies depending on how many service cards are installed in the rear 
of the frame.  While the reload is progressing, a series of status messages will 
appear in the HyperTerminal window which can be ignored. The reload is 
complete when you see the following prompts in the HyperTerminal dialogue 
window: 

 

 

Starting Heart

    

 [DONE] 

  Pulse: 

60 

BPM 

 

 

You may now retrieve the new settings by typing the following: 

 

 

ifinfo [ENTER]

 

 
 

7.  Close the HyperTerminal window and disconnect the serial crossover cable from 

the DB9 connector on the ZFCB.  Make sure the ZFCB card is still seated 
securely in its card socket and that the card locks are fully engaged after removing 
the serial cable.  Replace the EMI shield cover using the nine Phillips head 
countersink screws, oriented so that the LED status array is visible through the 
cover when secured.  Verify that the frame power supplies are switched on and 
replace the snap-on front cover.  The RCP-303 Express remote control panels will 
recognize the new frame settings automatically. 

  
 
 
 
If you have questions, comments, or suggestions, please contact us directly at Fortel 
DTV. 
 
Steve Addison    

770-806-0234 ext. 222    

steve.addision@forteldtv.com

 

James Griffin      

770-806-0234 ext. 111  

james.griffin@forteldtv.com

 

 
 
 

 
Fortel DTV Inc. 
3305 Breckinridge Blvd., Suite 118  

 

 

 

Duluth, GA 30096-6885  USA 
 
+1 (770) 806-0234  Main 
+1 (770) 806-0244  Fax 
 

http://www.forteldtv.com

 

Integrity FRM-501 Compact System Frame User Manual 

14 

Summary of Contents for Integrity FRM-501

Page 1: ...Integrity FRM 501 Compact System Frame User Manual Revised Dec 1 2004 Fortel DTV 3305 Breckinridge Blvd Suite 118 Duluth GA 30096 USA 770 806 0234 Integrity FRM 501 Compact System Frame User Manual 1 ...

Page 2: ... one to four AV cards and either a blank faceplate or a local control panel model RCP 502 Configurations FRM 501 Blank faceplate and ZFCB controller card installed four AV card slots FRM 501 with RCP 502 Local control panel and ZFCB controller card installed four AV card slots Integrity FRM 501 Compact System Frame User Manual 2 ...

Page 3: ...he LAN for all AV cards installed in FRM 501 FRM 504 or FRM 304 frames equipped with a ZFCB controller PSU 502 External redundant power supply module It plugs into the 12V DC connector on the rear of the FRM 501 frame If the integral main power supply should fail the PSU 502 will carry the load until the frame can be removed from service for repair of the failed integral supply Integrity FRM 501 C...

Page 4: ...t System Frame with rack mount ears attached Instructions Hardware kit with rear rack mount brackets and all mounting screws Short Adapter Bracket Qty 2 Long Extension Bracket Qty 2 Clip Nut 2 10 32 x 1 Black screws Qty 6 10 32 x Bright Screws Qty 6 Integrity FRM 501 Compact System Frame User Manual 4 ...

Page 5: ...e baseline of the ZFCB card J1 is at the right hand end below the ZFCB nearest the fan J2 is at the left head end below the ZFCB farthest from the fan Connect the LAN jumper cable to J1 Connect the PWR cable to J2 Route these cables to the front of the frame keeping them under the ZFCB card as you re install it in its card guides and sockets Retain the ZFCB in its socket by locking the two card ej...

Page 6: ... require a simple rule to be followed to activate the full feature set of each card The rule is this Video in slot N Audio in slot N 1 Simply put this means that if slot N 1 then slot N 1 2 In the FRM 501 frame a related AV pair can be used in 1 and 2 or 2 and 3 or 3 and 4 but not in 4 and 1 Once the slot has been selected remove its blank cover plate by loosening the two captive screws and pullin...

Page 7: ...rarily affix one extension rail to the rear equipment rack rails Mark the extension rail hole which lines up with the slot in the short bracket Remove the extension bracket from the rack and attach a clip nut at the marked position on the extension Reinstall the extension rail attaching it to the rear equipment rack rail using a single black finish 10 32 x 1 screw then securing the extension to th...

Page 8: ... power source may be added by connecting it to the unswitched 12V DC input connector on the rear of the frame Fortel DTV offers a suitable supply as an optional accessory model PSU 501 Other 12V DC 10A supplies may also be used When an external 12 VDC supply is connected and power applied to it the frame will remain on even if the AC main switch is turned off 1 2 3 4 Fuse Holder AC Power Input DC ...

Page 9: ...al control panel is installed and network communication is not required you must either install a crossover cable between the two RJ45 connectors or connect both to a 100 Mbps Ethernet switch When both connections are made to the Ethernet switch the control panel may also be used to serve as a remote for all other Integrity products on the network Connecting Genlock Reference An external black bur...

Page 10: ... control card is booting The green LINK lamp will light if the Ethernet connection is good The green ACT lamp lights only when a command is received from or sent to the network AC Power Switch OFF Position ON Position Front Panel Status LEDs System fault or booting Network is connected ZFCB transmitting receiving ACT ATTN LINK Integrity FRM 501 Compact System Frame User Manual 10 ...

Page 11: ...l continue to operate but remote control access will be suspended until a cold boot restart is performed Cards will not be accessible by a control panel until the update is completed Performing this update requires a FRM 501 frame with a ZFCB installed a DB9 serial crossover cable your PC equipped with an available serial port and a HyperTerminal utility IP Address Rules All Integrity system frame...

Page 12: ...able serial port to the DB9M connector located on the front edge of the ZFCB control board 3 Open a HyperTerminal window on your PC and set session variables to the following values 38400 Bits per second 8 Data bits N Parity 1 Stop Bit None Flow Control 4 In the connection dialog window press ENTER to verify you have established communication with the ZFCB If successful this will be indicated by t...

Page 13: ...ou must re enter the old value Enter the desired Gateway in the format 192 168 0 1 192 168 0 2 ENTER type your new value i e 192 168 0 2 Note If this is a value you do not wish to change you must re enter the old value After entering the new Gateway value the cbconfig utility will display this prompt Press ENTER to enable new settings q to quit without using Press ENTER to accept the new settings ...

Page 14: ... ZFCB Make sure the ZFCB card is still seated securely in its card socket and that the card locks are fully engaged after removing the serial cable Replace the EMI shield cover using the nine Phillips head countersink screws oriented so that the LED status array is visible through the cover when secured Verify that the frame power supplies are switched on and replace the snap on front cover The RC...

Reviews: