Shelf Manager CLI
Fortinet Technologies Inc.
setbootdev <addr> <fru-id | amc-addr> <boot-device>
setcommandpolicy <Enable|Disable> <NetFn> <CMD> [<channel>] [<LUN>]
setextracted <addr> <fru_id>
setfanlevel <addr> <fru_id> <state>
setfanpolicy <addr> <fru_id> <ENABLE | DISABLE [timeout]> [-s <addr> | site_type <fru_id> |
site_number]
setfruledstate <addr> <fru_id> <LedId> | ALL <LedOp | tail> [LedColor]
setfunctionpolicy <EnableDisableMask> <NetFn> <CMD> [<channel>] [<LUN>]
sethysteresis <addr> [ lun: ]<sensor_id> | <sensor name> pos | neg <value>
setipmbstate <addr> A | B [<link>] 0|1
setlanconf <address> <channel number> <parameter number> | parameter name <parameters ...>
setlanconfig <channel number> <parameter number> | parameter name <parameters ...>
setlocked <addr> <fru_id> <value>
setpefconfig <parameter name> | <parameter number> [<set selector>] <parameters ...>
setpowerlevel <addr> <fru_id> [<pwr_lvl> | OFF] [Copy]
setsensordata <addr> [ lun: ]<sensor_id> | <sensor name> [ reading [-r] <value> ]
[ assertion <mask> ] [ deassertion <mask> ]
[ event_data <b1> <b2> <b3> | event_data_no_offset <b1> <b2> <b3>]
setsensoreventenable <addr> [ lun: ]<sensor_id> | <sensor name> global [assertion_events
[deassertion_events]]
setsolconf <a>
Displaying more information about a command
Enter the following command to display more information about the threshold command:
# clia help threshold
IPM Sentry Shelf Manager Command Line Interpreter
Shows the threshold of the specified sensor
instead of <addr> user may use:
board <N>
shm <N>
to access the sensor on the specified board
getthreshold board 21 "IPMB LINK"
getthreshold 20 8
threshold [ <addr> [ [ lun: ]<sensor id> | <sensor name> ] ]
Enter the following command to display more information about the fruinfo command:
# clia help fruinfo
Pigeon Point Shelf Manager Command Line Interpreter
Display the FRU Info of the dedicated FRU in the readable format
instead of <addr> <fru_id> user may use:
power_supply <N> (valid in 2.x systems only)
fan_tray <N>
board <N>
shm <N>
to access the FRU on the specified board
fruinfo board 21 8
fruinfo power_supply 4
fruinfo <addr> <fru_id>
FortiGate-5144C 6.2.3 Chassis Guide
55