Hardware installation
Inserting a FortiGate-5001FA2-LENC board into a chassis
FortiGate-5001FA2-LENC Security System Guide
01-30000-76602-20080606
13
To change or verify the JP3 jumper setting
To complete this procedure, you need:
• A FortiGate-5001FA2-LENC board
• A tool for moving jumpers (optional)
• An electrostatic discharge (ESD) preventive wrist strap with connection cord
1
Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal
surface on a chassis or frame.
2
If you have installed the FortiGate-5001FA2-LENC board in a chassis, remove it.
For removal instructions, see
“Removing a FortiGate-5001FA2-LENC board from
a chassis” on page 17
.
3
Use
Figure 3
to locate the jumper settings on the circuit board.
4
If required, carefully move the jumper to the correct setting.
5
You can now insert the board into a chassis and verify that it is operating correctly.
For inserting instructions, see
“Inserting a FortiGate-5001FA2-LENC board into a
chassis” on page 13
.
Inserting a FortiGate-5001FA2-LENC board into a chassis
The following procedure describes how to correctly use the
FortiGate-5001FA2-LENC mounting components shown in
Figure 4
to insert a
FortiGate-5001FA2-LENC board into a FortiGate-5000 series chassis slot.
The FortiGate-5001FA2-LENC board left handle contacts to a hidden power
switch. The board must be fully installed in a chassis slot and this handle must be
closed and locked for the FortiGate-5001FA2-LENC board to receive power and
operate normally. If the FortiGate-5001FA2-LENC board is not receiving power,
the IPM LED glows blue and all other LEDs remain off.
It is important to carefully seat the FortiGate-5001FA2-LENC board all the way
into the chassis, to not use too much force on the handles, and to make sure that
the handles are properly locked and engaged with the hidden power switch. Only
then will the FortiGate-5001FA2-LENC board power-on and start up correctly.
!
Caution:
FortiGate-5001FA2-LENC boards must be protected from static discharge and
physical shock. Only handle or work with FortiGate-5001FA2-LENC boards at a static-free
workstation. Always wear a grounded electrostatic discharge (ESD) preventive wrist strap
when handling FortiGate-5001FA2-LENC boards.