FortiGate-5001FA2-LENC Security System Guide
14
01-30000-76602-20080606
Inserting a FortiGate-5001FA2-LENC board into a chassis
Hardware installation
Figure 4: FortiGate-5001FA2-LENC mounting components
Before inserting the FortiGate-5001FA2-LENC board in a chassis
Before installing the FortiGate-5001FA2-LENC board in a chassis you should
verify that the RAM DIMMs are installed and the JP3 jumper is set correctly. You
can also install the SFP transceivers before inserting the board.
•
“RAM DIMMs” on page 9
•
“Installing SFP transceivers” on page 10
•
“Changing FortiGate-5001FA2-LENC jumper settings” on page 11
Insertion procedure
FortiGate-5001FA2-LENC boards are hot swappable. The procedure for inserting
the FortiGate-5001FA2-LENC board into a FortiGate-5000 series chassis slot is
the same whether or not the FortiGate-5000 series chassis is powered on.
To insert a FortiGate-5001FA2-LENC board into a FortiGate-5000 series
chassis
To complete this procedure, you need:
• A FortiGate-5001FA2-LENC board
Closed
Open
Alignment Pin
Retention
Screw
Lock
Handle
Alignment Pin
Retention
Screw
Lock
Handle
Switch Contact
Power
Switch
Lock
Left Handle
!
Caution:
Do not carry the FortiGate-5001FA2-LENC board by holding the handles. When
inserting or removing the FortiGate-5001FA2-LENC board from a chassis slot, handle the
board by the front panel. The handles are designed for positioning and locking the
FortiGate-5001FA2-LENC board into a slot in a chassis only and should not be used for
handling the board. If the handles become bent or damaged the FortiGate-5001FA2-LENC
board may not align correctly in the chassis slot and the handles may not activate the
power switch.