Quick Configuration Guide
FortiGate-5001FA2-LENC base backplane data communication
FortiGate-5001FA2-LENC Security System Guide
01-30000-76602-20080606
31
In a FortiGate-5140 or FortiGate-5050 chassis, FortiGate-5001FA2-LENC base
backplane communication requires one or two FortiSwitch-5003 boards.
A FortiSwitch-5003 board installed in chassis slot 1 provides communication on
the port9 interface. A FortiSwitch-5003 board installed in chassis slot 2 provides
communication on the port10 interface. The FortiGate-5020 chassis supports
base backplane data communication for both interfaces with no additions or
changes to the chassis.
For details and configuration examples of FortiGate-5001FA2-LENC base
backplane communication using the FortiSwitch-5003 board, see the
FortiGate-
5000 Base Backplane Communication Guide
.
To enable base backplane data communication from the
FortiGate-5001FA2-LENC web-based manager
From the FortiGate-5001FA2-LENC web-based manager use the following steps
to enable base backplane data communication.
1
Go to
System > Network > Interface
.
2
Select Show backplane interfaces.
The port9 and port10 backplane interfaces now appear in the Interface list.
Figure 9: FortiGate-5001FA2-LENC interface list with backplane interfaces enabled
To enable base backplane data communication from the
FortiGate-5001FA2-LENC CLI
From the FortiGate-5001FA2-LENC board CLI you can use the following steps to
enable base backplane data communication.
1
Enter the following command to show the backplane interfaces:
config system global
set show-backplane-intf enable
end
The port9 and port10 backplane interfaces now appear in all Interface lists.