FortiGate-5020 chassis 

FortiGate-5020 front panel

FortiGate-5020   Chassis Guide
01-30000-0043-20061207

5

FortiGate-5020 chassis

You can install one or two FortiGate-5000 series modules in the two slots of the 
FortiGate-5020 ATCA chassis. The FortiGate-5020 is a 4U chassis that contains 
two redundant AC to DC power supplies that connect to AC power. The 
FortiGate-5020 chassis also includes an internal cooling fan tray. If both slots 
contain FortiGate-5001SX modules, the FortiGate-5020 chassis provides a total 
of 16 Gigabit ethernet FortiGate interfaces.

If you install the same FortiGate-5000 series module in both slots, you can 
configure the modules to operate as an HA cluster. HA heartbeat communications 
between the modules uses the FortiGate-5020 backplane. No extra switching or 
other connections are required.

The FortiGate-5020 chassis can only be connected to AC power. Two redundant 
FortiGate-5020/5050 power supplies are factory installed in the FortiGate-5020 
chassis.

FortiGate-5020 front panel

Figure 1

 shows the front of a FortiGate-5020 chassis. Two FortiGate-5002FB2 

modules are installed. The FortiGate-5020/5050 power supplies are factory 
installed behind the panel at the top of the chassis. The power LEDs for the power 
supplies are visible on the front panel as well.

Figure 1: FortiGate-5020 front panel with two FortiGate-5002FB2 modules

PSU A

PSU B

PWR

IPM

USB

5

3

4

5

6

CONSOLE

STATUS

1

6

2

ALT

ON/OFF

RESET

PWR

IPM

USB

5

3

4

5

6

CONSOLE

STATUS

1

6

2

ALT

ON/OFF

RESET

Hot-swappable FortiGate-5020/5050

power supplies (behind panel)

Power LEDs

PSU A

PSU B

FortiGate-5002FB2

modules

Hot swappable cooling fan tray

(accessable from back panel)

!

Caution: 

Do not operate the FortiGate-5020 chassis with open slots on the front panel. For 

optimum cooling performance and safety, the slots must contain a FortiGate-5000 series 
module or an air baffle slot filler.

Summary of Contents for FortiGate 5020

Page 1: ...scribes FortiGate 5020 hardware features and how to install the FortiGate 5020 chassis The most recent versions of this and all FortiGate 5000 series documents are available from the FortiGate 5000 pa...

Page 2: ...ies component in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Make sure the operating ambient temperature does not ex...

Page 3: ...to AC power 7 Turning on FortiGate 5020 chassis power 8 Inserting FortiGate 5000 series modules into a FortiGate 5020 chassis 8 Base backplane communications and HA between FortiGate 5020 chassis 9 F...

Page 4: ...FortiGate 5020 Chassis Guide 4 01 30000 0043 20061207 Contents...

Page 5: ...chassis can only be connected to AC power Two redundant FortiGate 5020 5050 power supplies are factory installed in the FortiGate 5020 chassis FortiGate 5020 front panel Figure 1 shows the front of a...

Page 6: ...5020 chassis back panel Physical description of the FortiGate 5020 chassis The FortiGate 5020 chassis is a 4U chassis that can be installed in a standard 19 inch rack Table 1 describes the physical c...

Page 7: ...n make sure that the amount of air flow required for safe operation of the FortiGate 5020 chassis is not compromised Connecting the FortiGate 5020 chassis to AC power The AC power connectors on the ba...

Page 8: ...Gate 5020 chassis Arrange the modules in slots as required for your configuration FortiGate 5001SX or FortiGate 5001FA2 modules can be installed in both of the FortiGate 5020 slots Your FortiGate 5020...

Page 9: ...e if you have two FortiGate 5001SX modules installed in a FortiGate 5020 chassis you can enable the base backplane interfaces for data communication and then you can communicate data from port9 on one...

Page 10: ...ort2 connects to the Internet Port3 to port8 are available to be connected as HA heartbeat interfaces This example uses port7 and port8 as the HA heartbeat interfaces Figure 3 Network and HA heartbeat...

Page 11: ...mmunications and HA between FortiGate 5020 chassis FortiGate HA between two FortiGate 5020 chassis FortiGate 5020 Chassis Guide 01 30000 0043 20061207 11 Figure 4 FortiGate 5001SX HA heartbeat interfa...

Page 12: ...FortiGate 5020 Chassis Guide 12 01 30000 0043 20061207 FortiGate HA between two FortiGate 5020 chassis Base backplane communications and HA between FortiGate 5020 chassis...

Page 13: ...n CD shipped with your Fortinet product The documents on this CD are current for your product at shipping time For the latest versions of all Fortinet documentation see the Fortinet Technical Document...

Page 14: ...idge FortiClient FortiGate FortiGate Unified Threat Management System FortiGuard FortiGuard Antispam FortiGuard Antivirus FortiGuard Intrusion FortiGuard Web FortiLog FortiAnalyzer FortiManager Fortin...

Reviews: