Using the shelf manager CLI
board
FortiGate-5060 Chassis Guide
01-400-129494-20110912
35
•
Setting alarm output
Use
minor
,
major
and
critical
to set the corresponding alarm output. These actions
are cumulative; that is, after the commands
clia alarm minor
and
clia alarm
major
, both minor and major alarms will be set.
board
clia board [-v] [<physical-slot-address>]
Enter
clia
board
without any parameters to view information about each IPM controller
and about each additional FRU controlled by these controllers.
This command is different from most of the rest of the commands because its works with
ATCA boards and takes as arguments physical slot numbers, instead of IPM controller
addresses and FRU device IDs.
This makes this command easier to use when boards may not include an IPM controller
and therefore, are not easily addressable using the IPMB address – FRU device ID pair.
Viewing information about a board
Enter the following command to view information about a particular board, for example the
board in physical slot 4 (logical slot 4, IPMB address 88):
# clia board 4
Pigeon Point Shelf Manager Command Line Interpreter
Physical Slot # 4
88: Entity: (0xa0, 0x60) Maximum FRU device ID: 0x00
PICMG Version 2.1
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State
Change (0x0)
88: FRU # 0
Entity: (0xa0, 0x60)
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State
Change (0x0)
Device ID String: "FG5005A"
Add
–v
to the command to display more information (verbose).
The command output includes the hot swap state.
M4
is the normal hot swap state.
lists the FRU states defined in the PICMG 3.0 specification as follows: