getthreshold/threshold
Using the shelf manager CLI
FortiGate-5060 Chassis Guide
42
01-400-129494-20110912
Display threshold sensor values for a physical slot
For example, to display the values for threshold sensors on physical slot 4 (in this
example, a FortiGate-5005FA2), enter the following command:
# clia threshold 88
Pigeon Point Shelf Manager Command Line Interpreter
88: LUN: 0, Sensor # 4 ("CPU1 Voltage")
Type: Threshold (0x01), "Voltage" (0x02)
Lower Non-Critical Threshold, Raw Data: 0x6c Processed data:
1.058400 Volts
Lower Critical Threshold, Raw Data: 0x67 Processed data:
1.009400 Volts
Lower Non-Recoverable Threshold, Raw Data: 0x61 Processed
data: 0.950600 Volts
Upper Non-Critical Threshold, Raw Data: 0xa9 Processed data:
1.656200 Volts
Upper Critical Threshold, Raw Data: 0xae Processed data:
1.705200 Volts
Upper Non-Recoverable Threshold, Raw Data: 0xb3 Processed
data: 1.754200 Volts
88: LUN: 0, Sensor # 5 ("CPU2 Voltage")
Type: Threshold (0x01), "Voltage" (0x02)
Lower Non-Critical Threshold, Raw Data: 0x6c Processed data:
1.058400 Volts
Lower Critical Threshold, Raw Data: 0x67 Processed data:
1.009400 Volts
Lower Non-Recoverable Threshold, Raw Data: 0x61 Processed
data: 0.950600 Volts
Upper Non-Critical Threshold, Raw Data: 0xa9 Processed data:
1.656200 Volts
Upper Critical Threshold, Raw Data: 0xae Processed data:
1.705200 Volts
Upper Non-Recoverable Threshold, Raw Data: 0xb3 Processed
data: 1.754200 Volts
88: LUN: 0, Sensor # 6 ("+5.0V")
Type: Threshold (0x01), "Voltage" (0x02)
Lower Non-Critical Threshold, Raw Data: 0xbe Processed data:
4.655000 Volts
Lower Critical Threshold, Raw Data: 0xb8 Processed data:
4.508000 Volts
Lower Non-Recoverable Threshold, Raw Data: 0xb0 Processed
data: 4.312000 Volts
Upper Non-Critical Threshold, Raw Data: 0xdb Processed data:
5.365500 Volts
Upper Critical Threshold, Raw Data: 0xe1 Processed data:
5.512500 Volts
Upper Non-Recoverable Threshold, Raw Data: 0xe9 Processed
data: 5.708500 Volts
88: LUN: 0, Sensor # 7 ("+3.3V")