Using the shelf manager CLI
help
FortiGate-5060 Chassis Guide
01-400-129494-20110912
45
•
Display threshold sensor values for a specific sensor
Enter the following command to display the threshold for sensor 13, which for the
FortiGate-5005FA2 is the CPU board temperature:
# clia threshold 88 13
Pigeon Point Shelf Manager Command Line Interpreter
88: LUN: 0, Sensor # 13 ("CPU Board Temp")
Type: Threshold (0x01), "Temperature" (0x01)
Upper Non-Critical Threshold, Raw Data: 0x4b Processed data:
75.000000 degrees C
Upper Critical Threshold, Raw Data: 0x51 Processed data:
81.000000 degrees C
Upper Non-Recoverable Threshold, Raw Data: 0x55 Processed
data: 85.000000 degrees C
You can also enter the name of the sensor in quotes:
# clia threshold 88 "CPU Board Temp"
Pigeon Point Shelf Manager Command Line Interpreter
88: LUN: 0, Sensor # 13 ("CPU Board Temp")
Type: Threshold (0x01), "Temperature" (0x01)
Upper Non-Critical Threshold, Raw Data: 0x4b Processed data:
75.000000 degrees C
Upper Critical Threshold, Raw Data: 0x51 Processed data:
81.000000 degrees C
Upper Non-Recoverable Threshold, Raw Data: 0x55 Processed
data: 85.000000 degrees C
help
clia help [<command> [<sub_command>] ]
This command displays help information about supported commands and their syntax.
Enter the command with no parameters to display all commands,
# clia help
Pigeon Point Shelf Manager Command Line Interpreter
Command Line Interface command set:
Parameters are case insensitive
In general:
IPMB address is hexadecimal ALWAYS.
All other numbers may be either decimal and hexadecimal (0x
notation required for hexadecimal notation)
-v turns on verbose output
activate <addr> <fru_id>
airfilterreplaced [<date>]
alarm <alarm status/action>
amcportstate [-v] <ipmc> [ amc <N> | <fru_id> ]
board [slot_number]
boardreset <slot number>