Using the shelf manager CLI
minfanlevel
FortiGate-5060 Chassis Guide
01-400-129494-20110912
49
•
Display the FRU Info of the dedicated FRU in the readable
format
instead of <addr> <fru_id> user may use:
power_supply <N> (valid in 2.x systems only)
fan_tray <N>
board <N>
shm <N>
to access the FRU on the specified board
fruinfo board 21 8
fruinfo power_supply 4
fruinfo <addr> <fru_id>
minfanlevel
clia minfanlevel [<level>]
This command displays or sets the minimum fan level. Under normal conditions, the
cooling management algorithm gradually decreases the level for the fans in the chassis
while thermal conditions stay normal. The cooling management algorithm will not try to
decrease the fan level below the minimum level specified by the configuration parameter
MIN_FAN_LEVEL
or by this command. The minimum fan level affects only the automatic
management of the fan level by the cooling management facility.
Enter the command with no parameters to display the current minimum fan level.
Enter the command with an integer to set the minimum fan level.