sensordata
Using the shelf manager CLI
FortiGate-5060 Chassis Guide
52
01-400-129494-20110912
88: LUN: 0, Sensor # 13 ("CPU Board Temp")
Type: Threshold (0x01), "Temperature" (0x01)
Belongs to entity: (0x3, 96) [FRU # 0]
# clia sensor 88 "CPU Board Temp"
Pigeon Point Shelf Manager Command Line Interpreter
88: LUN: 0, Sensor # 13 ("CPU Board Temp")
Type: Threshold (0x01), "Temperature" (0x01)
Belongs to entity: (0x3, 96) [FRU # 0]
sensordata
clia sensordata [-v] [-t] [<IPMB-address> [<sensor-name> |
[<lun>:]<sensor-number>]]
This command displays the actual value of the specified sensor or sensors (for a threshold
based sensor) or the currently asserted states (for a discrete sensor). The target sensor is
selected by entering the IPM controller’s IPMB address and the sensor number or the
sensor name. If you do not include the sensor name or number, the command displays the
values of all sensors on the specified IPM controller. If you do not enter any parameters,
the command displays values of all known sensors.
The following information is displayed for each sensor:
• IPMB address of the owning IPM controller.
• Sensor number, sensor name (device ID string from the SDR) and the LUN by which
the sensor can be accessed.
• The sensor type and event/reading type code.
• The sensor value (for threshold-based sensors) or the mask of currently asserted
states (for discrete sensors) in raw form.
• The threshold crossing status, in hexadecimal format and with decoding.
Use the
-t
to displayed information only for threshold-based sensors, that have at least
one of their thresholds crossed.
Example for physical slot 4 (logical slot 4 and IPMB address 88) and sensor 13, a
temperature sensor:
# clia sensordata 88 13
Pigeon Point Shelf Manager Command Line Interpreter
88: LUN: 0, Sensor # 13 ("CPU Board Temp")
Type: Threshold (0x01), "Temperature" (0x01)
Status: 0xc0
All event messages enabled from this sensor
Sensor scanning enabled
Initial update completed
Raw data: 44 (0x2c)
Processed data: 44.000000 degrees C
Status: 0x00