Using the shelf manager CLI
Using the chassis system event log (SEL)
FortiGate-5060 Chassis Guide
01-400-129494-20110912
77
•
86: LUN: 0, Sensor # 8 ("+2.5V CPU 1")
Type: Threshold (0x01), "Voltage" (0x02)
Belongs to entity (0x14, 96): [FRU # 0]
86: LUN: 0, Sensor # 9 ("+2.5V CPU 2")
Type: Threshold (0x01), "Voltage" (0x02)
Belongs to entity (0x14, 96): [FRU # 0]
86: LUN: 0, Sensor # 10 ("+1.2V 1")
Type: Threshold (0x01), "Voltage" (0x02)
Belongs to entity (0x14, 96): [FRU # 0]
86: LUN: 0, Sensor # 11 ("+1.2V 2")
Type: Threshold (0x01), "Voltage" (0x02)
Belongs to entity (0x14, 96): [FRU # 0]
86: LUN: 0, Sensor # 3 ("BTI")
Type: Discrete (0x6f), "OEM reserved" (0xe0)
Belongs to entity (0xa0, 96): [FRU # 0]
86: LUN: 0, Sensor # 12 ("Incoming Air-Flo")
Type: Threshold (0x01), "Temperature" (0x01)
Belongs to entity (0x3, 96): [FRU # 0]
86: LUN: 0, Sensor # 13 ("CPU Board Temp")
Type: Threshold (0x01), "Temperature" (0x01)
Belongs to entity (0x3, 96): [FRU # 0]
86: LUN: 0, Sensor # 14 ("CPU1 Temp")
Type: Threshold (0x01), "Temperature" (0x01)
Belongs to entity (0x3, 96): [FRU # 0]
Sample sections of SEL Output
Shows the active shelf manager moving from M0 to M4 state (active and working):
0x0285: Event: at Jan 1 00:01:46 1970; from:(0x20,0,0);
sensor:(0xf0,0); event:0x6f(asserted): HotSwap: FRU 0 M0-
>M1, Cause=0x0
0x0286: Event: at Jan 1 00:01:51 1970; from:(0x20,0,0);
sensor:(0xf0,0); event:0x6f(asserted): HotSwap: FRU 0 M1-
>M2, Cause=0x2
0x0287: Event: at Jan 1 00:01:51 1970; from:(0x20,0,0);
sensor:(0xf0,0); event:0x6f(asserted): HotSwap: FRU 0 M2-
>M3, Cause=0x1
0x0288: Event: at Jan 1 00:01:52 1970; from:(0x20,0,0);
sensor:(0xf0,0); event:0x6f(asserted): HotSwap: FRU 0 M3-
>M4, Cause=0x0
Shows fan #2 in middle Fan Tray is spinning slower than required:
0x018D: Event: at Jan 1 00:02:15 1970; from:(0x10,0,0);
sensor:(0x04,10); event:0x1(asserted): "Upper Critical",
Threshold: 0xff, Reading: 0xff
Shows a low voltage warning on the backup battery on shelf manager 1: