FortiGate-5140-R Power and cooling enhancements to support the FortiSwitch-5203B
4
01-400-175441-20120709
5
Press enter to connect to the CLI.
6
At the
login
prompt enter the shelf manager user name and password.
7
Use the following command to start the vi editor and edit the shelf manager
configuration file and change mini-fan level to 8.
# vi /etc/shelfman.conf.ACB-IV
The contents of the shelfman.conf file are displayed. Note that the
MIN_FAN_LEVEL
is 3:
FAN_LEVEL_STEP_DOWN = 1
NORMAL_STABLE_TIME = 1800
IPMB_LINK_ISOLATION_TIMEOUT = 60
INITIAL_FAN_LEVEL = 8
MIN_FAN_LEVEL = 3
REDUNDANCY_NET_ADAPTER = "usb0"
8
Enter
I
to edit, move cursor and change
MIN_FAN_LEVEL=3
to
MIN_FAN_LEVEL=8
.
9
Press
Esc
.
10
Enter
:w
to save.
11
Enter
:q
to quit.
12
Enter the following commands to change the power setting of slot1 and slot2
clia shelf pwrcapability 41 0xfe 220
clia shelf pwrcapability 42 0xfe 220
13
Power cycle the chassis to make sure the changes take effect.
Verifying the changes
1
When the chassis has started back up enter the following command to check the
minimum fan level:
# clia minfanlevel
Pigeon Point Shelf Manager Command Line Interpreter
Minimal Fan Level is 8
Dynamic Minimum Fan Level is 8
Baud Rate (bps)
9600
Data bits
8
Parity
None
Stop bits
1
Flow Control
None