Enter the following command to check the power setting for each chassis slot:
# clia shelf -v pm
The following command output shows slots 1 and 2 supplying 220 Watts of power
and all other slots supplying 200 Watts.
Pigeon Point Shelf Manager Command Line Interpreter
PICMG Shelf Activation And Power Management Record (ID=0x12)
Version = 1
Allowance for FRU Activation Readiness: 20 seconds
FRU Activation and Power Description Count: 17
Hw Address: 41 (82), FRU ID: 0xfe, Maximum FRU Power
Capabilities:
220 Watts
Shelf Manager Controlled Activation: Enabled
Shelf Manager Controlled Deactivation: Enabled
Delay Before Next Power On: 0.0 seconds
Currently Assigned Power: 150.0 Watts
Hw Address: 42 (84), FRU ID: 0xfe, Maximum FRU Power
Capabilities:
220 Watts
Shelf Manager Controlled Activation: Enabled
Shelf Manager Controlled Deactivation: Enabled
Delay Before Next Power On: 0.0 seconds
Currently Assigned Power: 150.0 Watts
Hw Address: 43 (86), FRU ID: 0xfe, Maximum FRU Power
Capabilities:
200 Watts
Shelf Manager Controlled Activation: Enabled
Shelf Manager Controlled Deactivation: Enabled
Delay Before Next Power On: 0.0 seconds
Currently Assigned Power: 0.0 Watts
Hw Address: 44 (88), FRU ID: 0xfe, Maximum FRU Power
Capabilities:
200 Watts
Shelf Manager Controlled Activation: Enabled
Shelf Manager Controlled Deactivation: Enabled
Delay Before Next Power On: 0.0 seconds
Currently Assigned Power: 0.0 Watts
Hw Address: 45 (8a), FRU ID: 0xfe, Maximum FRU Power
Capabilities:
200 Watts
Shelf Manager Controlled Activation: Enabled
Shelf Manager Controlled Deactivation: Enabled
Delay Before Next Power On: 0.0 seconds
Currently Assigned Power: 0.0 Watts
Hw Address: 46 (8c), FRU ID: 0xfe, Maximum FRU Power
Capabilities:
200 Watts
Shelf Manager Controlled Activation: Enabled
Shelf Manager Controlled Deactivation: Enabled
Delay Before Next Power On: 0.0 seconds
Currently Assigned Power: 0.0 Watts