Changing the shelf manager IP address and default gateway
Using the shelf manager CLI
FortiGate-5140B Chassis Guide
40
01-500-156415-20151104
Display the FRU information for a FRU
# clia fruinfo <IPMB_address> <FRU_id>
Change the speed for a fan tray
# clia setfanlevel <IPMB-address> <FRU_id> <speed>
<speed>
can be from 0 to 14.
Display the contents of the system event log (sel)
# clia sel
Clear the system event log (sel)
# clia sel clear
Changing the shelf manager IP address and default gateway
You can configure the shelf manager IP address and gateway so that you can use telnet
or ssh to access the Shelf Manager instead of the serial console port. You can view the
current LAN configuration with the following command:
# clia getlanconfig 1
Pigeon Point Shelf Manager Command Line Interpreter
Authentication Type Support: 0x15 ( None MD5 Straight
Password/Key )
Authentication Type Enables:
Callback level: 0x00
User level: 0x15 ( "None" "MD5" "Straight Password/Key" )
Operator level: 0x15 ( "None" "MD5" "Straight Password/Key" )
Administrator level: 0x15 ( "None" "MD5" "Straight
Password/Key" )
OEM level: 0x00
IP Address: 192.168.0.2
IP Address Source: Static Address (Manually Configured) (0x01)
MAC Address: 00:50:c2:3f:f0:9a
Subnet Mask: 255.255.255.0
IPv4 Header Parameters: 0x40:0x40:0x10
Primary RMCP Port Number: 0x026f
Secondary RMCP Port Number: 0x0298
BMC-generated ARP Control: 0x02
Enable BMC-generated ARP Response
Gratuitous ARP Interval: 2.0 seconds
Default Gateway Address: 192.168.0.1
Default Gateway MAC Address: 00:09:0f:09:32:03
Backup Gateway Address: 0.0.0.0
Backup Gateway MAC Address: N/A
Community String: "public"
Number of Destinations: 16
Destination Type:
DST Type # 2, Type: Unacknowledged PET Trap Destination
(0x00), ACK Timeout / Retry Interval: 0 seconds,
Retries: 0