FortiGate-7000F hardware assembly and rack mounting
Fortinet Technologies Inc.
Front air filter kit data and power cable management
Managing AC power cords
1
. Connect AC power cords to
the PSUs and cable clamps.
2
. Run the power cords out the
side seals at the bottom of both
filter kit side brackets.
Rubber
retainer
Installing horizontal cable mount levers
Insert the other end of the mount
lever into the top hole in the bracket
on the other side of the chassis.
From the inside, insert the mount
lever through the top hole in the side
bracket and extend it a short distance
past the side bracket.
Press the mount lever down until
held in place by the rubber retainer
in each bracket.
1
2
3
1
2
3
Cable management
Tie cables to the mount lever
using the second round of the
cable tie.
Attach cable ties to the mount levers.
Maintain a greater than 1-inch
(2.5-cm) network cable
bend radius
Power cord clamps
You can install power cord clamps onto the front of the chassis beside each PSU. Install the clamps by inserting them
into the holes adjacent each PSU. Use the clamps to secure the AC power cords so they are not accidentally
disconnected.
FortiGate-7121F System Guide
25