FortiGate-7000F System Management Module
Fortinet Technologies Inc.
Chassis slot number
Name
IPMB Address (FRUID)
passive 0x22
11
FPM11
0x96
9
FPM9
0x92
7
FPM7
0x8E
5
FPM5
0x8A
3
FPM3
0x86
1
FIM1
0x82
2
FIM2
0x84
4
FPM4
0x88
6
FPM6
0x8C
8
FPM8
0x90
10
FPM10
0x94
12
FPM12
0x98
You can use the IPMB address or chassis slot number to reference a chassis slot when entering commands in the SMM
CLI. For example, enter either of the following commands to display sensor readings for the FIM in slot 2:
sensor 0x84
sensor 2
When command syntax descriptions in this chapter include the <slot> variable you can replace it with a slot number (1 to
12) or an IPMB address number (0x82 to 0x98).
Rebooting an FIM or FPM from the SMC SDI CLI
A common use of the SMC SDI CLI is being able to remotely reboot a FIM or FPM.
From any SMC SDI CLI use the following command to reboot the FPM in slot 3:
mc reset 3 warm
Use the following command to power off the FPM in slot 4:
fru deactivate 4
Use the following command to power on the FIM in slot 2 (IPMI address 0x84):
fru activate 0x84