Appliance Setup
7.
SSH to the Collector and run following script to register Collectors:
phProvisionCollector --add <
user
> '<
password
>' <
Super IP or Host
> <
Organization
>
<
CollectorName
>
The password should be enclosed in single quotes to ensure that any non-alphanumeric characters are escaped.
a.
Set
user
and
password
use the admin User Name and password for the Supervisor.
b.
Set
Super IP or Host
as the Supervisor's IP address.
c.
Set
Organization
as the name of an organization created on the Super.
d.
Set
CollectorName
from
by command line, for example:
# phProvisionCollector --add admin Admin*11 172.30.53.130 ORG1289 CO1289
A message will display after the completion:
Continuing to provision the Collector
This collector is registered successfully. Normal Exit and restart of phMonitor
after collector license registration.
The Collector will reboot during the Registration.
8.
Go to
ADMIN > Health > Collector Health
to see the status of the Collector.
Step 6: Using FortiSIEM
Refer to the
for detailed information about using FortiSIEM.
FortiSIEM 6.3.1 500F Collector Configuration Guide
14
Fortinet Technologies Inc.