1. To avoid vibration and noise, make sure the unit is installed securely and firmly.
2. Install the unit where the sunlight does not shine directly.

If the unit is installed under direct sunlight, build an awning to shade the cabinet.

3. There should be no obstacle, such as a fence or wall, within 50cm from the back of the

cabinet because it will prevent  heat radiation of the condenser.
Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

4. Install the unit a little obliquely outward not to leak the condensed water into the room

(about 10mm with level).

5. Install the unit with its bottom portion 75~150cm above the floor level.
6. The power cord must be connected to an independent circuit. The yellow/green

wire must be earthed.

Over 50cm

About 10mm

FENCE

AWNING

75-150cm

Over 50cm

About 10mm

FENCE

AWNING

75-150cm

*
* The appliance shall be installed in accordance with local wiring regulations.

  All side louvers of the cabinet must remain exposed to the outside of the structure.

CAUTION

Select the best location

INSTALLATION INSTRUCTION

Summary of Contents for FWAC08M16

Page 1: ...l Model FWAC08M16 FWAC10M16 FWAC13M16 FWAC19M16 使用或安裝本產品前 請仔細閱讀本說明書 及所有安全注意事項 並請妥善保存 以備日後參考查閱 Before operating or installing the appliance please read this manual and all the safety instructions thoroughly and retain it for future reference ...

Page 2: ...cerning use of appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the air conditioner If the power cord is damaged it must be replaced by the manufacturer the authorised service technician or qualified person in order to avoid a hazard Make sure the unit power and the circuit breaker are turned off before cleaning and maintenance R...

Page 3: ... may cause failure of machine or electric shock It may cause fire and electric shock It may cause electric shock or fire If the power cord is damaged it must be replaced by the manufac turer or an authorised service centre or a qualified person in order to avoid a hazard This could damage your health Incorrect installation may cause fire and electric shock It may cause electric shock It may cause ...

Page 4: ...nditioner to preserve precision devices food pets plants and art objects Turn off the main power when not using the unit for a prolonged period If water enters the unit turn the unit off and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service technician 3 It may cause failure of appliance or accident Appearance may be deteriorated due to chang...

Page 5: ...cision devices food pets plants and art objects otherwise it could harm the property 1 Do not touch the metal parts of the unit when removing the filter Injuries may occur when handling sharp metal edges 2 Do not use water to clean the air conditioner inner Water enter the unit can degrade the insulation and may lead to electric shock 3 Make sure the unit power and the circuit breaker are turned o...

Page 6: ...wire brown Fig 1 Accessories Seal Used on drain joint 1 1 Screw Drain Joint 1 Drain Tray 2 12000Btu 4 18000Btu Fig 2 Wall outlet Switch 1 Power cord conductors are distinguished according to color as follows see Fig 1 2 Please contact the manufacturer its service agent or a qualified person when replace the power cord 3 Be sure that the unit being correctly grounded The wall outlet switch should b...

Page 7: ...FF will completely shut off the unit Fan Mode HIGH FAN MED FAN LOW FAN Rotate the knob to select your choice of fan speeds for air circulation Note 1 When selecting a fan speed the compressor will not run 2 When change the cool mode from LOW COOL to HIGH COOL rotate the knob as slow as possible Do not change the operation mode between LOW COOL and HIGH COOL too often OPERATION INSTRUCTION OFF HIGH...

Page 8: ...r rotate the thermostat knob to adjust the cool settings during operation in cool mode do not rotate it again in 3 minutes otherwise the fuse may blow due to an overload of the unit AUTO SWING OFF ON AUTO SWING Horizontal air flow adjustment automatically When the AUTO SWING switch is turned to ON position the vertical louvers automatically oscillate right and left sweeping the cold air alternatel...

Page 9: ...tment Always keep the top or bottom blades in horizontality This can prevent water drops condensed on the front panel of the unit 8 Vent Control The vent control is located above the control panel The operation method is different on different models see the following figures For maximum cooling efficiency CLOSE the vent This will allow internal air circulation OPEN the vent to discharge stale air...

Page 10: ...re with screws provided 4 Connect the drain hose to the outlet located at one side of the drain tray You can purchase the drain hose or tubing locally to satisfy your particular needs Suggestion To ensure the condensed water drain off smoothly always keep the drain outlet of the the drain tray downward when install the drain tray See the following procedures to perform bottom drainage If you choos...

Page 11: ... cooling efficiency of the air conditioner 4 Install the unit a little obliquely outward not to leak the condensed water into the room about 10mm with level 5 Install the unit with its bottom portion 75 150cm above the floor level 6 The power cord must be connected to an independent circuit The yellow green wire must be earthed Over 50cm About 10mm FENCE AWNING 75 150cm Over 50cm About 10mm FENCE ...

Page 12: ...oles in the wall to ensure the cabinet can be well supported Holes from the outside through to the cavity should be sealed The cabinet should slope down towards the rear by about 10mm to allow water drainage during operation Step 3 Install and secure the cabinet into the wall Ensure the foam seals are not damaged Flash seal or fill gaps around the inside and outside to provide satisfactory appeara...

Page 13: ...binet See Fig 8 5 Install two chassis fixing brackets by two fixing screws See Fig 5 Step 4 Install the frame 1 Install the frame and connect the coupler plugs make sure not to interfere with the temperature sensor cable See Fig 9 2 Fix the screws on the frame See Fig 3 Step 5 Install the air filter and front panel 1 Install the air filter into the frame s slot from upside to underside See Fig 2 2...

Page 14: ...tripped Check the house fuse circuit breaker box and replace the fuse or reset the breaker Power failure If power failure occurs switch off and disconnect unplug the power cord When power is restored reconnect plug in the power cord switch on the power and wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload Airflow is restricted Make sure there are no curta...

Page 15: ...14 SPECIFICATIONS TYPES Btu h BODY DIMENSION mm W x H x D WIRING SIZE mm 2 9000 9000 and 12000 450x346x585 600x380x560 3 1 0 3 1 5 18000 660x428x680 3 2 5 ...

Page 16: ...e plugged or connected into a specific 220 240V socket Please make sure the plug is fully plugged in before use Do not use any adapter or extension cord This appliance is a high energy consumption product please do not use it with other high energy consumption products in the same supply socket THE APPLIANCE IS FOR HOUSEHOLD USE ONLY ENVIRONMENT Do not throw away the appliance with the normal hous...

Reviews: