Engaging lever /
no damage
functions easily
lever engaged
(lever remains engaged)
Motor, magnetic brake / holding force OK
(FOR U can not be pushed with
engaging lever in drive-position)
Motor, drive /
no damage
fixed securely
drive noise
Component : Drive
Assessment
Defective
OK
Description
(Component / inspection for)
63
Issued: 23.01.2008
If the error should occur again, you
can find information about
troubleshooting and appropriate
remedies in the lists in sections 16.2
and 16.3.
Switch the FOR U off.
Ensure that the main plug (1) is
inserted tightly.
Ensure that the battery case (2) is
firmly inserted in the chassis.
Switch the FOR U on after waiting
about 1 minute.
Before troubleshooting
Before you start troubleshooting, please
observe the following points to avoid
simple error sources.
16.1
16.0 Troubleshooting
and inspection
Maintenance
FOR U MN3/4