• When replacing the battery, make sure to use the same type and number of sealed lead-acid batteries specified.
• Do not dispose of batteries in a fire. Batteries may explode if exposed to high temperatures.
• Never try to open a battery. The cell contains a toxic electrolyte which is harmful to the skin and eyes.
• Replace the fuse only with the same type and amperage in order to avoid fire hazards.
• Do not dismantle the UPS system.

2. Operation

2-1. Unpacking and inspection

Remove the UPS from its package and make sure that all the following items are included:

• One UPS unit
• One user manual
• One monitoring software CD (ForzaTracker)
• One USB cable
• IEC C13 to Argentina Type I cable
• Warranty certificate

Carefully inspect the UPS to check for any damages that may have occurred during shipping.

Should any evidence of damage be found or if some parts are missing, do not turn the UPS on; you must immediately notify the carrier 
or dealer where you purchased the unit.

2-2. UPS diagram 

  Front 

panel 

view 

      Rear 

panel 

view

FDC-1002T-A/FDC- 2002T-A

1. AC input
2. Input circuit breaker
3. USB communication port
4. RS-232 communication port
5. SNMP intelligent slot (optional)
6. Output receptacles

2.3. Installation procedure

Choose location

Install the UPS unit in any protected environment that provides adequate airflow around the unit, and free from excessive dust, corrosive 
fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high. 
For best performance, keep the indoor temperature between 0° C and 40° C. Place the UPS unit at least 20 cm away from monitors to 
avoid interference.

2-4. UPS connections
2-4.1 UPS input connection

Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords or adapter plugs.

2-4.2 UPS output connection

• For socket-type outputs, simply connect devices to the outlets.

Communication port:

To allow for unattended UPS shutdown/start-up and status monitoring, connect one end of the communication cable to the 
USB/RS-232 port, and the other end to the communication port of your PC. With the monitoring software installed, you can schedule 
UPS shutdown/start-up and monitor its status through a PC.

The UPS is equipped with intelligent slot perfect for either SNMP card. When installing a SNMP card in the UPS, it will provide advanced 
communication and monitoring options.

Note:

 The USB and RS-232 ports cannot be used at the same time.

Turning on the UPS

Press the 

ON/Mute

 button on the front panel for two seconds to power on the UPS.

Note: 

The battery charges fully during the first five hours of normal operation. Do not expect full battery run capability during this initial 

charge period.

2-5. ForzaTracker monitoring software

ForzaTracker is a new generation of UPS monitoring software, which provides user-friendly interface to monitor and control your UPS 
system. This unique software provides safe auto-shutdown for multi-computer systems during power failures. With this software, users 
can monitor and control any UPS on the same LAN no matter how far they might be from the UPS.

Intelligent slot

RS-232 port

USB port 

Summary of Contents for FDC-1002T-A

Page 1: ...3 y e a r w a r r a n t y User Manual Uninterruptible Power Supply System FDC 1002T A 2002T A Ajustes 06_20_2017...

Page 2: ...ables for connections between mains the UPS and equipment shockproof outlet Use CE marked power cables to connect the loads to the UPS system During the installation of this equipment make sure that t...

Page 3: ...humidity is high For best performance keep the indoor temperature between 0 C and 40 C Place the UPS unit at least 20 cm away from monitors to avoid interference 2 4 UPS connections 2 4 1 UPS input c...

Page 4: ...ut frequency battery voltage output voltage and output frequency Setting mode Press and hold this button for 5 seconds to enter the UPS configuration menu while UPS is in standby or bypass mode Down k...

Page 5: ...ce Setting Parameter 3 Output voltage For 200 208 220 230 240 VAC you may choose any of the following output voltages 200 The output voltage is 200VAC 208 The output voltage is 208VAC 220 The output v...

Page 6: ...mmable outlets backup time in minutes from 0 999 in order to connect non critical devices on battery mode Interface Setting Parameter 3 Sets up backup interval on battery mode for default outlets 0 99...

Page 7: ...ocket Symptom Possible cause Solution Fault code 28 and the icon become illuminated on the LCD display and the alarm starts beeping continuously The and icons become illuminated on the LCD display and...

Page 8: ...ion 200 240VAC 160VAC 140VAC 120VAC 110VAC 5 based on load percentage 100 80 80 70 70 60 60 0 Low line transfer voltage 15V 300VAC 5 High line transfer voltage 10V 40 70Hz 0 99 at 100 load 15 at 100 l...