Installation procedure for Windows users:
1. Use the supplied CD or go to the website: http://www.forzaups.com.
2. After clicking the software icon, choose the required operation system.
3. Follow the on-screen instructions to install the software.
4. When you finished downloading all required files, enter the serial No (installation password):
5242-87f6-64re-di8d-986u
to install the
software (include the hyphens).
5. In order to access as Administrator, input the password:
111296
.
6. When your computer restarts, the management software will appear as a light blue round icon located in the system tray, near the
clock.
For Mac users, please refer to the ForzaTracker QIG inside the Mac folder.
3. Advanced operation
3-1. Description of buttons and functions
3-2. LCD panel
ON/Mute
button
OFF/Enter
button
Select
button
ON/Mute +
Select
button
Turn on the UPS: Press and hold the
ON/Mute
button for at least 2 seconds
to turn on the UPS.
Mute the alarm: When the UPS is on battery mode, press and hold this
button for at least 5 seconds to disable or enable the alarm system.
This command would not apply when warnings or errors occur.
Up key: Press this button to display previous selection in the UPS
configuration menu.
Switch to UPS self-test mode: Press and hold
ON/Mute
button for 5 seconds
to perform the self-test in AC mode, ECO mode, or converter mode.
Turn off the UPS: Press and hold this button for at least 2 seconds to turn
off the UPS in battery mode. The UPS will remain in standby mode under
normal power conditions or transfer to Bypass mode provided it has been
enabled previously by pressing this button.
Confirm selection key: Press this button to confirm the selection in the
UPS configuration menu.
Switch LCD message: Press this button to change the LCD message for
input voltage, input frequency, battery voltage, output voltage and output
frequency.
Setting mode: Press and hold this button for 5 seconds to enter the UPS
configuration menu while UPS is in standby or bypass mode.
Down key: Press this button to display the next selection in the UPS
configuration menu.
Switch to bypass mode: When the utility power is normal, press
ON/Mute
and
Select
buttons simultaneously for 5 seconds to transfer the UPS to
bypass mode. This action will be ineffective if the input voltage is not within
an acceptable range.
Button
Function
Mode operation
Info
Backup Time Info
Programmable
Output Info
Fault Info
Mute Operation
Output & Battery
Voltage Info
Input & Battery
Voltage Info
Battery Info
Load Info
Battery information
Indicates the output/input voltage, output/input frequency, and
battery voltage. V: voltage, Hz: frequency
Settings
Input/Output & Battery information
Load information
Operation mode information
Input & battery voltage information
Display
Indicates the remaining backup time in pie chart
Function
Backup time information
Fault information
Indicates the remaining backup time in numbers
H: hour, M: minute.
A warning or a fault indication has been triggered
Indicates that configuration parameters are being set
Load level indicator at 0-25%, 26-50%, 51-75%, and 76-100%
of its capacity
Overload indicator
Indicates the load or the UPS output is short circuited.
Indicates the UPS is connected to the mains
Indicates the battery is working
Indicates the bypass circuit is working
Indicates the ECO mode is enabled
Indicates the Inverter circuit is working
Indicates the output receptacle is working
Battery fault indicator
Low battery level and low voltage indicator
Battery level indicator at 0-25%, 26-50%, 51-75%, and 76-100%
of its capacity
Input voltage, frequency or battery voltage indicator.
VAC: Input voltage, VDC: battery voltage, Hz: input frequency
Warning and fault code indicators. The meaning of the code is listed
in the section below.
INPUT BATT
OUTPUT
V
Hz