Thank you for purchasing the Forza FX-1500/2200LCD Series UPS system. Please read 
this manual thoroughly to become familiar and enjoy all the features and benefits of this 
unit.

Important safety instructions

 

(save this manual)

This manual contains important information for the safe use and maintenance of the Forza FX 
Series UPS. Please follow the instructions and safety guidelines before unpacking, installing 
and operating the device.

CAUTION!

•  The voltage used by this UPS may be hazardous. The unit contains no user serviceable     
    parts; do not attempt to disassemble the unit. Only factory service technicians can perform  
    maintenance on the unit.
•  Connection to any other type of receptacle other than a two-pole, three-wire grounded  
    outlet may result in electrical shock.
•  In case of an emergency, turn the power switch “off” and disconnect the power cord from  
    the AC mains outlet.
•  Do not plug the UPS AC input power cord into its own output.
•  Do not connect any power strip or surge suppressor to the UPS.
•  Never connect non-computer-related peripheral devices, such as medical equipment, life- 
    support equipment, microwave ovens, or vacuum cleaners to the UPS.
•  Unplug the UPS before cleaning, and do not use liquid or spray detergents.

SAFE HANDLING OF BATTERIES

• The UPS contains an internal 12VDC, sealed, 6-cell lead-acid battery.
• To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
• Do not dispose of batteries in a fire. Batteries may explode if exposed to high temperatures.
• Never try to open a battery. The cell contains a toxic electrolyte which is harmful to the skin  
   and eyes.
• A battery can present the risk of short-circuit current and electrical shock. The following    
   precautions should be taken: 
        1) Remove watches, rings, or other metal objects from your hand. 
        2) Use tools with insulated handles. 
        3) Wear rubber gloves and boots. 
        4) Do not place tools or metal parts on the top of batteries.
• Disconnect charging source prior to connecting or disconnecting battery terminals. Servicing       
   of batteries should be performed or supervised by experts who possess the knowledge to 
   closely follow all required precautions. When replacing the battery, make sure to use the 
   same type and number of sealed lead-acid batteries specified.

SAFE OPERATING ENVIRONMENT

• Do not allow any kind of liquid or foreign object to enter this UPS unit. Do not place   
   beverages or any other containers with liquid on or nearby the unit.
• This unit should be installed and operated in an environment that meets the specified  
   conditions: (temperature-controlled indoor area location and free of conductive    
   contaminants). Do not install the UPS in locations nearby running water or excessively humid.
• To reduce the risk of overheating, do not cover the cooling vents. Avoid exposing the unit to   
   direct sunlight or installing the unit nearby heat-emitting appliances, such as electric heaters 
   or furnaces.
• The wall socket shall be located nearby the UPS and must be accessed very easily.

System introduction

The award-winning Forza FX Series, recognized by CHA as the best of its kind, offers an 
enhanced level of protection for your high performance office equipment, sensitive electronics 
and home-theater components. In addition to its reliable built-in automatic voltage regulator 
(AVR), the FX Series comes with the new ForzaTracker, a Power Management Software 
which controls and monitors the UPS via a USB connection. It also features a coaxial surge 
protection line and a convenient LCD display that indicates the operating status of the unit in 
real time. With 8 available outlets combined with its lightweight and compact design, this UPS 
fits perfectly in limited working spaces.   

Summary of Contents for FX-1500LCD

Page 1: ...3 y ear w arran ty FX 1500LCD 2200LCD FX 1500LCD U 2200LCD U Home theater Server network Power Protection...

Page 2: ...hort circuit current and electrical shock The following precautions should be taken 1 Remove watches rings or other metal objects from your hand 2 Use tools with insulated handles 3 Wear rubber gloves...

Page 3: ...C power input 6 Cooling fan 7 Six 6 outlets with surge protection battery backup and automatic voltage regulation AVR 8 Two 2 surge only protected outlets Installation and operation 1 Inspection Remov...

Page 4: ...ery prior to initial use Simply plug the unit into an appropriate AC outlet and allow it to recharge to full capacity for at least 8 hours 4 Connect to home theater or server PC Connect your TV receiv...

Page 5: ...hutdown via power monitoring software connect the USB as shown in the diagram below 7 Coaxial line connection Connect your incoming cable antenna digital satellite system line to the input connector o...

Page 6: ...every second 3 When in battery mode it will display as below And the mark will blink once every second Note If I P V 40V input voltage will be displayed as 000 4 When in off charging mode it will disp...

Page 7: ...1 Remove the front panel 2 Remove the battery cover 3 After removing battery cover gently extract the battery by disconnecting the two wires connected to the UPS Be sure to replace the same type of b...

Page 8: ...ose Reconnect the power cord properly For further assistance please contact us at tech forzaups com When replacing your batteries we recommend using a Forza FUB 1290 Software installation ForzaTracker...

Page 9: ...Technical specifications 2 years on batteries Calculated with a single PC plus monitor...

Page 10: ...consent from Forza Power Technologies LLC All other trademarks and brand names are registered trademarks of their respective owners Any mention of such is only intended for identification purposes and...

Reviews: