Loosen the snap

-

latches and pull out the drawer.

 

 

Insert the adapters. SC adapters are inserted with the guide tracks to the 
right, FC adapters with the guide tracks to the left. LC adapters are inserted 
with the lock to the right.

 

 
 
 
 
 
 
 

Fasten the cable to the two foremost punched out mounts in the drawer 
using tie

-

wraps. If a second cable is used this is fastened to the backmost 

mount and to the two upper holes in the rear wall as shown in picture 4.2.

 

 

Any excess cable must be handled outside of the panel.

 

 

 
 
 

 
 
 

The adapter plate may be lifted up and tilted to give easier access to the 
adapters on the inside. See picture 4.3. 

 

Loosen the screws on the side and lift the plate up and forward (as indicated 
by the arrow) until it rest in the end of the track. There it rests while the plate 
is tilted to the desired angle. Tighten the screw to secure it in that position. 

 

 
 
 
 
 
 
 

Clean the adapters. Distribute the fibres on the guiding crosses according to 
the adapters they shall be mounted in.  Clean the connectors and insert them 
in the adapters.  

 

 

Close the fibre guides

 

(see picture 3.2.1).

 

 

4.1 Interior of the panel

 

4.2 Fastening the cables 

 

4. Installing pre

-

terminated cable with tight buffered fibre

 

4.4 Finished panel. 

 

4.3 The adapter plate may be tilted

 

2

 

1

 

Summary of Contents for FP60

Page 1: ...connectors may be prepolished and without glue or meant for glue and polishing in the field It may also be connectors intended for direct splicing to the fibre Glue free connectors may be e g FAST or UniCam Connectors for direct splicing to the fibre may be e g FuseConnect 2 Materials Tools Socket wrench 12 mm or 13 mm For use with FC or ST adapters Torx 25 screwdriver PZ2 screwdriver Heat gun Add...

Page 2: ...2 This gives more space in front of the panel which may be beneficial e g if the distance to the doors in the front is very short When the panel is to be mounted in an ETSI metric rack the brackets are turned and assembled as shown in picture 3 3 After all installations make sure the fibre guides are closed see picture 3 1 1 19 assembly 3 1 2 Offset 19 assembly 3 1 3 ETSI assembly 3 2 1 Fibre guid...

Page 3: ...The adapter plate may be lifted up and tilted to give easier access to the adapters on the inside See picture 4 3 Loosen the screws on the side and lift the plate up and forward as indicated by the arrow until it rest in the end of the track There it rests while the plate is tilted to the desired angle Tighten the screw to secure it in that position Clean the adapters Distribute the fibres on the ...

Page 4: ...d turned to give easier access to the adapters on the inside See ch 4 3 Clean the adapters If the pigtails are more than 1 5 m long they should be cut to this length Clean the connectors and insert them in the adapters Attach splice protectors and splice the first 12 fibres put the fibres in the fibre guide crosses as shown in drawing 5 4 and place the splice protectors in the splice holders Fibre...

Page 5: ...urned to give easier access to the adapters on the inside See ch 4 3 Clean the adapters If the pigtails are more than 1 5 m long they should be cut to this length Clean the connectors and insert them in the adapters Attach splice protectors and splice the first 12 fibres put the fibres in the fibre guide crosses as shown in drawing 5 4 and place the splice protectors in the splice holders Fibre nr...

Page 6: ...ce holders in the two mid holes one for each holder as shown in drawing 6 5 They are fixed with rivets through one of the nut holes at the end of the holder shown as black dots Fasten the cable to the two foremost punched out mounts and to the lower hole in the back wall of the drawer using tie wraps Any excess cable must be handled outside of the panel The adapter plate may be lifted up and turne...

Page 7: ...he cable s as shown in drawing 5 1 Connectors for direct termination e g FAST UniCam FuseConnect are assembled according to the instructions from the supplier Then follow the instructions in chapter 4 figure 4 1 and onwards Prepare the cable s as shown in drawing 6 1 Make sure every fibre is cleaned and that all grease is removed Connectors for direct termination e g FAST UniCam FuseConnect are as...

Reviews: