background image

  

GB 

 
Function Icons and Buttons/Switches 

 

 

Info/Set point Button 

 

Increase Button/ Lights On/Off

 

 

Manual defrost

 

/Decrease Button

 

 

Exit/Stand-by Button 

 

Compressor Output 

 

Alarm 

 

Fan Output 

 

Defrost Output 

 

Light Output 

 

 

 
Set Point Display  

Press button 

 

briefly (at least half a second) to display the set point.   

 

Keypad Security Settings 

Press & release 

 then select 

 to show 

‘LOC’. Press and hold 

 

to change from ‘YES’ to ‘NO’. Leave 

for 10 seconds or briefly press 

 to resume to normal operation. 

 

Internal Light 

   

When pressed and released this button will switch on and off the display lights, with the unit running or in 
standby mode. If the lights do not come on this may be due to a fault warning, please see the 
troubleshooting section for more details. 

 
Shelves and Supports 

On delivery of the Multideck these parts are supplied wrapped 
inside the unit on the base shelf. These will require cleaning and 
fitting at first install. 
 
Supports

 can be fitted at three different angles, allowing the shelf to 

be tilted or level. Each shelf requires two supports (unless on a 1500 
or 1800 model then a third centre support is also required).  
Slot the first support into one side of the ladderacking at the height 
and angle the shelf will be required. Repeat this on the opposite side 
at the same position and angle (do the same for the centre support if applicable).  
Always remember that you will need to allow for breathing space around, not only the shelves, but the 
product. Remember to leave enough space between the supports when positioning on the ladderack. 

 
Shelves 

are fitted once the supports are in place. Hold the shelf level and above the supports making sure 

the flat surface is facing upwards. Position the supports so that they sit in the recess between the edge of 
the shelf and central moulding. When positioned correctly the shelf will drop down onto the supports and be 
secure.  
The base shelf will already be fitted but can be removed by lifting straight up and away. This does not have 
any supports and should not be removed when the unit is energised. 

 

Ticket Strips 

can be fitted when shelves are in situ or before fitting. 

These plastic mouldings are placed on the front of each shelf by firstly 
hooking underneath then once gripped pushing onto the shelf facet in 
an upwards motion. Make sure that all of the strip has secured itself 
to the shelf and is secure.  
 
All these parts are removable by carrying out the above instructions in 
reverse. This should be carried out at regular intervals for cleaning 
purposes. 

 
 