ISSUE DATE 10-09-03 REV. DATE 12/17 REV. LEVEL: 17 ECO 1-7383 OIPM P/N 8329
APPLICATION GUIDE
OUTDOOR COMFORT HEATING
Two (2) watts per square foot is equal to One (1) degree temperature rise. Heater installation
shall comply with all OIPM, NEC, and local restrictions.
MODEL
SERIES
RECOMMENDED
MOUNTING HEIGHT (FT.)
COVERAGE OF HEATHER
LENGTH X WIDTH (FT.)
WATT PER
SQUARE
FOOT
TEMPERATURE
RISE EXPECTED
222-60
8-10
10.5 X 9.5
32
15”
223-60
8-10
10.5 X 9.5
48
24”
342-60
10-12
14 X 12
30
15”
343-60
10-12
14 X 12
45
23”
462-60
10-12
15 X 12
41
20”
463-60
10-12
15 X 12
61
30”
SPOT HEATING (OUTDOOR) APPLICATION CHART
INDOOR SPOT HEATING
One (1) watt per square foot is equal to One (1) degree temperature rise. When comfort spot heating
people, two heaters should be used to heat both sides of the individual. Heater installation shall comply
with all OIPM, NEC, and local restrictions.
MODEL
SERIES
RECOMMENDED
MOUNTING HEIGHT (FT.)
A*
COVERAGE OF HEATER
LENGTH X WIDTH (FT.)
WATT PER
SQUARE
FOOT
TEMPERATURE
RISE EXPECTED
222-60
8-10
13 X 12
21
20”
223-60
10-12
15 X 14
23
23”
222-30
12-14
8.5 X 7.5
50
50”
342-60
8-10
14 X 12
30
30”
343-60
10-12
16 X 14
24
34”
462-60
12-14
19 X 16
24
24”
463-60
12-14
19 X 16
36
36”
SPOT HEATING (INDOOR) APPLICATION CHART
*Clearances to combustibles must be maintained regardless of recommended mounting height. See
page 8 for clearance distances.
6’ 8”
A