background image

  

Issue Date: 12-02-97      Rev. Date: 05-05-08        Rev. Level: 06        EC0: 1-5888                OIPM P/N 8300       Page 1 of 6

 

REQUIRED CLEARANCE 

NOTE:  Heaters should be a minimum 3" from ceiling, 24" 
from a vertical surface and a minimum 6 ft. from the floor.

 

WARNING!

 

DO NOT ATTEMPT TO INSTALL, OPERATE, OR SERVICE THIS PRODUCT BEFORE READING ALL 

INSTRUCTIONS CAREFULLY. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN 

FIREPERSONAL

 

INJURY

 

AND/OR 

PROPERTY DAMAGE!

 

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE

.

 

Fostoria multipurpose infrared heaters are designed to 
provide efficient spot heating anywhere a 120V, 60 Hz. 
bonded receptacle is available.  Use in farm buildings, 
garages, factories, truck docks, storefronts, terminals, etc. 

Not for indoor residential use.

  Available with two 450 

watt individually operated quartz tubes, or one 550 watt 
quartz tube.  Heaters are equipped with lamp guard, two 4-
ft. suspension chains and an 8-ft. three-wire bonding 
(grounding) type cordset.   

 

The housing for model FFH-912B is made from heavy 
gauge steel, with a baked-on brown enamel finish.  Model 
FFH-512A has a gold anodized aluminum reflector and 
housing. 

 

Caution:  Not recommended for use in potentially 
explosive atmospheres (spray areas, chemical 
storage areas, etc.) or where excessive moisture 
may contact unit (car washes, etc.).  For specific 
applications, consult local codes or your 
insurance company

.

 

 

DESCRIPTION 

FFH-512A 

Heat source

…………..…..…...…One 550W, 120V, 4.6 amp quartz tube 

                                                                         5000 hour life expectancy 

Housing

………….…………………….…..0.040 gold anodized aluminum                                               

Dimensions

………………………….…..…..…22” L x 4 1/2” W x 3 1/4” H  

 

FFH-912B 

Heat source

….…………...….....Two 450W, 120V, 3.8 amp quartz tubes 

                                                                         5000 hour life expectancy 

Housing

…………...……………………………Painted galvannealed steel 

Dimensions

…………….……………….….16 1/2” L x 5 3/4” W x 4 3/4” H 

 

FFH-512A and FFH-912B 

Lamp guard

….…………………….….…..0.105 chrome plated steel wire 

Suspension

……………………………………………Two, 4ft. jack chains 

Power Cord

………………………8ft. 18/3 cordset with Nema 5-15P plug 

Power Source

………………………………………..………….120V, 60Hz 

 

 

SPECIFICATIONS 

Read all instructions before using this heater: 

 

WARNING:  DO NOT DEPEND UPON A THERMOSTAT OR 
OTHER SWITCH AS THE SOLE MEANS OF 
DISCONNECTING POWER WHEN INSTALLING OR 
SERVICING THE HEATER.  ALWAYS UNPLUG THE HEATER.  
FAILURE TO DO SO COULD RESULT IN FATAL ELECTRIC 
SHOCK. 

 
1.  This heater is hot when in use.  To avoid burns, do not let 

bare skin touch hot surfaces. Keep combustible materials, 
such as furniture, pillows, bedding, papers, clothes, and 
curtains at least 6 feet (2m) from the front of the heater and 
keep them away from the sides and rear. 

 
2.  Extreme caution is necessary when any heater is used by or 

near children or invalids, and whenever the heater is left 
operating and unattended. 

 
3.  Connect to properly bonded (grounded) outlets only. 
 
4.  Always unplug the heater when not in use. To disconnect 

heater, turn controls to off, then remove plug from outlet. 

IMPORTANT SAFETY INFORMATION 

5.  Do not operate any heater with a damaged cord or plug or 

after the heater malfunctions, has been dropped or damaged 
in any manner.  Return heater to authorized repair facility for 
examination, electrical or mechanical adjustment, or repair. 

 
6.  This heater is not intended for use in bathrooms, laundry 

areas and similar indoor locations.  Never locate heater where 
it may fall into a bathtub or other water container. 

 
7.  Do not run cord under carpeting.  Do not cover cord with 

throw rugs, runners, or the like.  Arrange cord away from 
traffic area and where it will not be tripped over. 

 

8.

 

Do not insert or allow foreign objects to enter any ventilation 
or exhaust opening as this may cause an electric shock or 
fire, or damage the heater.

                             

 

 

9.  Do not use outdoors. 
 
10.  Use this heater only as described in this manual.  Any other 

use not recommended by the manufacturer may cause fire, 
electric shock, or injury to persons. 

 

 

 

ELECTRIC PORTABLE HEATER 

MODEL & PART NO.’s: 

 

FFH-912B

 

(08827814) 

 

FFH-512A

 

(08838900)

 

If you have questions about the

product you have purchased or would 

like to leave us feedback please 

contact us via our website 

www.fostoriaindustries.com 

or by calling 1-800-495-4525.

 

OPERATION – INSTALLATION – PARTS MANUAL 

 

Summary of Contents for FFH-912B

Page 1: ...ructions before using this heater WARNING DO NOT DEPEND UPON A THERMOSTAT OR OTHER SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE HEATER ALWAYS UNPLUG THE HEATER FAILURE TO DO SO COULD RESULT IN FATAL ELECTRIC SHOCK 1 This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Keep combustible materials such as furniture pillows bedding p...

Page 2: ... dry with a clean soft cloth Periodically wipe the quartz tube s with alcohol and a clean soft cloth Allow to dry Repair or replace damaged cordsets immediately INSTALLATION OF HEATING ELEMENT MODEL FFH 512A Refer to Figure 2 1 Loosen screws on ceramic insulators 2 Position quartz tube in slots 3 Carefully wrap pigtail of quartz tube clockwise around screw and tighten screw Be sure to leave some s...

Page 3: ... QTY 1 1 1 2 1 2 2 2 1 4 4 1 Part No for FFH 512A 43882 001 03440300 04400802 32113 002 03190700 5081 32110 001 28942 001 REF NO 12 13 14 15 16 17 18 19 20 21 22 23 DESCRIPTION PHD P Screw 8 32 X3 8 Strain relief Jack chain hdwr pkg Two 4 chains Quartz tube 450W 120V Quartz tube 550W 120V Wire channel Socket shield 18 ga silicone wire not shown Sleeving not shown HHD Screw 8 x 1 2 PHM P Screw 10 3...

Page 4: ...eado Suspensión Dos cadenas de gato de 1 2 metros 4 pies Cordón eléctrico 18 3 de 2 4 metros 8 pies con clavija Nema 5 15P Fuente de electricidad 120 V 60 Hz IMPORTANTE INFORMACIÓN DE SEGURIDAD 1 ADVERTENCIA EVITE USAR TERMOSTATOS O TODO TIPO DE INTERRUPTOR COMO MEDIO ÚNICO DE DESCONECTAR LA ALIMENTACIÓN ELÉCTRICA AL INSTALAR O DAR SERVICIO AL CALENTADOR SIEMPRE DESCONECTE EL INTERRUPTOR PRINCIPAL...

Page 5: ... presentes pueden aumentarse o disminuirse apagando o encendiendo los elementos calefactores El modelo FFH 912B cuenta con dos fuentes caloríficas tubos de cuarzo y apagando un tubo no se afecta la dirección del calor El ciclado constituye una forma alternativa al apagado y encendido de los tubos y se logra fácilmente mediante un controlador de entrada o un temporizador de porcentaje Ambos disposi...

Page 6: ...nillo PHM 10 32 x 1 Tuerca hexagonal 10 32 Tuerca sujetacables Pieza No para FFH 912B 08050514 08060114 08060300 08060400 08060529 07715002 03110300 03171300 03401939 1041 3605 CANT 1 1 1 2 1 2 2 2 1 4 4 1 Pieza No para FFH 512A 43882 001 03440300 04400802 32113 002 03190700 5081 32110 001 28942 001 NO REF 12 13 14 15 16 17 18 19 20 21 22 23 DESCRIPCIÓN Tornillo PHD P 8 32 x 3 8 Protección contra ...