Goodrive20 Series VFD
Function parameter list
-62-
Function
code
Name
Description
Default
Modify
when the FWD/REV terminal is valid, if the
VFD stops due to a stop command given by
another source, the VFD does not run again
after the stop command disappears even if
the control terminal FWD/REV is still valid.
To make the VFD run, you need to trigger
FWD/REV
again,
for
example,
PLC
single-cycle stop, fixed-length stop, and valid
STOP/RST stop during terminal control.
(See
P07.04
).
P05.14
S1
switch-on
delay
The function code defines the delay time
corresponding to the electrical level change
when the programmable input terminals
switch on to switch off.
Si electrical level
Si valid
invalid
invalid
Switch-on
delay
Switch-off
delay
valid
Setting range: 0.000
–50.000s
0.000s
○
P05.15
S1
switch-off
delay
0.000s
○
P05.16
S2
switch-on
delay
0.000s
○
P05.17
S2
switch-off
delay
0.000s
○
P05.18
S3
switch-on
delay
0.000s
○
P05.19
S3
switch-off
delay
0.000s
○
P05.20
S4
switch-on
delay
0.000s
○
P05.21
S4
switch-off
delay
0.000s
○
P05.22
S5
switch-on
delay
0.000s