Goodrive20 Series VFD
Function parameter list
-92-
Function
code
Name
Description
Default
Modify
step
ACC/DEC
time
selection
Functio
n code
Binary bit
Step
ACC
/DEC
1
ACC
/DEC
2
ACC
/DEC
3
ACC/
DEC
4
P10.34
BIT1
BIT0
0
00
01
10
11
BIT3
BIT2
1
00
01
10
11
BIT5
BIT4
2
00
01
10
11
BIT7
BIT6
3
00
01
10
11
BIT9
BIT8
4
00
01
10
11
BIT11 BIT10
5
00
01
10
11
BIT13 BIT12
6
00
01
10
11
BIT15 BIT14
7
00
01
10
11
P10.35
BIT1
BIT0
8
00
01
10
11
BIT3
BIT2
9
00
01
10
11
BIT5
BIT4
10
00
01
10
11
BIT7
BIT6
11
00
01
10
11
BIT9
BIT8
12
00
01
10
11
BIT11 BIT10 13
00
01
10
11
BIT13 BIT12 14
00
01
10
11
BIT15 BIT14 15
00
01
10
11
Select corresponding ACC/DEC time, and
then convert 16-bit binary number into decimal
number, and then set corresponding function
codes.
Setting range: -0x0000
–0xFFFF
P10.35
Simple
PLC 8
–15
step
ACC/DEC
time
selection
0x0000
○
P10.36
PLC
restart
mode
0: Restart from the first step, namely if the
VFD stops during running (caused by stop
command, fault or power down), it will run
from the first step after restart.
1: Continue running from the step frequency
when interruption occurred, namely if the VFD
stops during running (caused by stop
command or fault), it will record the running
time of current step, and enters this step
automatically after restart, then continue
running at the frequency defined by this step
in the remaining time.
0
◎