OWNER’S MANUAL /
HÉLIA 44
OWNER’S MANUAL /
HÉLIA 44
35
34
The 220V or 110V AC network is powered by:
- Either a dock extension
- Either a power generator (optional)
The switching choice is automatic. The whole network is protected by a 30mA differential circuit breaker.
Each function is protected by a specific circuit breaker.
Connection of the dock extension:
Check the cable’s condition.
If the cable is damaged, replace it with an identical cable.
Connect the dock extension
by rolling it out fully or
start the power generator.
Check that the current is flowing
using the light indicator on the 220V unit (or 110V depending on the
chosen option).
Switch on the differential circuit breaker
and the circuit breaker(s) for the function required.
Never connect an extension with a damp plug.
WARNING
220V /110V AC network (optional)
3
4
1
2
a
V
Dock line
b
V
220 V circuit breakers panel
c
V
110 V circuit breakers panel
(depending on the chosen option )
ELECTRICITY (NEXT)
Systems
4
a
V
Inverter charger
b
V
Panel control
Inverter charger 12V/220V or 12V/110V (optional)
T
he boat can be fitted with an inverter charger.
This inverter charger
is powered with 12V by a service battery pack
and protected by a circuit breakers panel.
For use and maintenance, refer to the manufacturer’s manual
During a long stop, put the loader on OFF mode on the chart table next to the
electric panel.
WARNING
All versions
b
c
a
a
b
All versions
a
Summary of Contents for Helia 44 2019
Page 1: ...H LIA 44 OWNER S MANUAL...
Page 11: ...V Deck 22 24 V Hull saloon 25 29 3 Equipments H LIA 44...
Page 16: ...V Steering system 32 V Electricity 33 35 V Gas circuit 36 V Water 37 45 Systems 4 H LIA 44...
Page 24: ...Manoverboard prevention and man recovery 5 H LIA 44...
Page 26: ...Fire protection 6 H LIA 44...