Chapter 2 Installation Introduction 

2.1 General 

The DTU must be installed correctly to make it work properly. 

Warning: Forbid to install the DTU when powered! 

2.2 Encasement List 

 

Name Quantity 

Remark 

DTU host 

 

Antenna 1 

 

Power adapter 

 

RS232 data cable 

optional 

RS485 data cable 

optional 

Manual CD 

 

Certification card 

 

Maintenance card 

 

 

 

 

 

 

2.3 Installation and Cable Connection 

Dimension

: (unit: mm) 

 

58.5

35

28

28

22

8

25

Ф3

Ф5

4

 

 
 
Installation of SIM/UIM card: 

Firstly power off the DTU, and press the out button of the SIM/UIM card outlet 

with a needle object. Then the SIM/UIM card sheath will flick out at once. Put 

SIM/UIM card into the card sheath (Pay attention to put the side which has metal point 

Summary of Contents for F2403

Page 1: ...ion Technology Co Ltd Add J1 J2 3rd Floor No 44 GuanRi Road SoftWare Park XiaMen China 1 Zip Code 361008 Tel 86 592 6300320 86 592 6300321 86 592 6300322 Fax 86 592 5912735 http www four faith com www fourfaith com F2403 WCDMA HSDPA HSUPA DTU USER MANUAL ...

Page 2: ... nt te en nt ts s Chapter 1 Brief Introduction of Product 3 1 1 General 3 1 2 Product Features 3 1 3 System Component 3 1 4 Working Principle 3 1 5 Technical Specification 4 Chapter 2 Installation Introduction 5 2 1 General 5 2 2 Encasement List 5 2 3 Installation and Cable Connection 5 2 4 Power 7 2 5 Indicator Lights Introduction 7 Chapter 3 Configuration 8 3 1 Configuration Connection 8 3 2 Con...

Page 3: ...dustrial MCU 100M Design with standard TCP IP protocol stack Adopt smart online keeping technology to make sure that DTU is always online Support double data centers one main and another backup Support multi data centers It can support 5 data centers at the same time Support dynamic domain name DDNS and IP access to data center Support several work modes Support hardware and software WDT Easy to u...

Page 4: ...900 2100MHz Quad band EGSM 850 900 1800 1900MHz GPRS EDGE CLASS 12 HSUPA 5 76Mbps UL HSDPA 7 2Mbps DL UMTS 384kbps DL UL EDGE 236 8kbps DL UL GPRS 85 6Mbps DL 42 8Kbps UL Interface RS232 485 serial port rates 110 230400bits s Indicator lights Power ACT Online Antenna interface standard SMA female interface 50 ohm SIM UIM interface standard user card interface Power interface standard 3 PIN power j...

Page 5: ...ng Forbid to install the DTU when powered 2 2 Encasement List Name Quantity Remark DTU host 1 Antenna 1 Power adapter 1 RS232 data cable 1 optional RS485 data cable 1 optional Manual CD 1 Certification card 1 Maintenance card 1 2 3 Installation and Cable Connection Dimension unit mm 58 5 35 28 28 22 8 25 Ф3 Ф5 4 Installation of SIM UIM card Firstly power off the DTU and press the out button of the...

Page 6: ...of antenna Screw the SMA male pin of the antenna to the female SMA outlet of the DTU tightly Warning The antenna must be screwed tightly or the singal quality of antenna will be influenced Installation of cable Insert DB9F end of the RS232 RS485 data cable into the DB9M interface of DTU and connect the other end with user s device The signal connection of the RS232 data cable is as follows The sig...

Page 7: ... range of the DTU is DC 5 35V Warning When we use other power we should make sure that the power can supply power above 4W We recommend user to use the standard DC 12V 0 5A power adaptor 2 5 Indicator Lights Introduction The DTU provides three indicator lights Power ACT Online Indicator Light State Introduction Power Bright DTU is powered on Dark DTU is powered off ACT Twinkle Data is communicatin...

Page 8: ...through AT command so any device with serial port can configure it Before configuration with extended AT command you should make DTU enter configure state The steps how to make DTU enter configure state please refer to appendix The following describes how to configure DTU with the configure software tool At the same time it gives out the corresponding AT command of each configuration item 3 2 1 Ru...

Page 9: ...rvice Center DSC Data Center Number DTU support two Data Service Center methods to transmit data Main and Backup DTU always tries to connect with the Main DSC If fails to connect with Main DSC it will connect with Backup DSC at once Note If no Backup DSC exists please configure the Backup DSC same as Main DSC Multi Data Service Center DTU can connect with at most five DSC at the same time All the ...

Page 10: ... the Backup DSC port AT PTSEC xxx xxx The port value Multi DSC Configuration When Data Center Number is greater than 1 this setting is valid For example setting the Data Center Number as 3 Main Center 2nd Center 3rd Center work as these three DSC AT Command of the 2 5 DSC IP address or domain name AT IPADn xxx n is 1 4 correspond to center 2 5 xxx The IP address or domain name AT Command of the 2 ...

Page 11: ... 4 correspond to center 2 5 DNS server aaa bbb ccc ddd is the DNS server IP address 3 2 3 2 DTU Settings DTU WorkMode According to different application requirements there are several protocol workmode to choose PROT Heartbeat packet with TCP protocol Data transmission with TCP protocol heartbeat packet and application data transmission are in the same TCP connection TRNS DTU work as a common WCDM...

Page 12: ... data to transmit DTU can be triggered online ready for data transmission There are total five methods to make DTU online AUTO DTU always keeps online SMSD send a special short message to make DTU online CTRL make DTU online through a phone call to DTU DATA send special serial data to make DTU online MIXD the combination of SMSD CTRL DATA DTU will be online when meet one of these three trigger met...

Page 13: ...tion Baudrate 110 110 bps 300 300 bps 600 600 bps 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 bps 14400 14400 bps 19200 19200 bps 38400 38400 bps 56000 56000 bps 57600 57600 bps 115200 115200 bps AT Command AT IPR xxx xxx one of the above baudrate Auto Back To Main Server 0 No 1 Yes This item is only valid when you set Data Center Number as 1 In this mode DTU will switch to backup center w...

Page 14: ...xxxx the SIM card phone number Bytes Interval The time interval used to determine whether the serial data frame transmission has completed DTU will send the serial data to the center when two bytes transmit time interval larger than this item value AT Command AT BYTEINT xxx xxx bytes interval time value millisecond Custom Register String This item is only valid when the WorkMode is TCST It s the s...

Page 15: ...Times and Reconnect Time Interval items When DTU fail to connect to the center with the configured Retry Time It will sleep Reconnect Time Interval time then start next retry Connect Retry Times AT Command AT RETRY xxx xxx times try to connect to the center Reconnect Time Interval AT Command AT RDLWT xxx xxx the sleep time until next retry Transfer meanning 0 Yes enable transfer meaning 1 No disab...

Page 16: ...APN AT APN xxxx xxxx access point name AT Command of Username AT USERNAME xxx xxx username AT Command of Password AT PASSWORD xxx xxx password AT Command of Call Center AT CENT xxx xxx call center phone number of ISP SMS Center Your local SMS center number AT Command AT SMSC xxx xxx your local SMS center number Heartbeat Interval Time interval sent heartbeat packet unit is second AT Command AT POL...

Page 17: ...SMSDPSWD xxx xxx SMS content to trigger DTU online Data Trigger Password This item is valid only when the Trigger Type is DATA or MIXD DTU will keeps in idle state until it receives the trigger on data then it will connect to the center It will return to the idle state when receives trigger off data AT Command of Data Trigger On Password AT DONPSWD xxx xxx data trigger on password AT Command of da...

Page 18: ...unit is second 3 3 Functions Clear Output Clear the output information Version Display Show the software and hardware version Signal Value Display current wireless signal value Factory setting Restore to factory settings Show Config Show current DTU settings Show Baudrate Display the communication baudrate Auto Detect Simple way to determine whether DTU work fine Save Output Save the output info t...

Page 19: ...22 Fax 86 592 5912735 http www four faith com www fourfaith com 3 4 Work State Switch This tool can work in two states Config and Communication Config This state is used to configure parameters of DTU Communication This state is used as a common serial communication tool Reboot Device Enter Communication State This function button is used to reboot DTU and make the software switch to Communication...

Page 20: ...com www fourfaith com Chapter 4 Appendix The following steps decribe how to make DTU enter configure state with the Windows XP Hyper Terminal 1 Press Start Æ Programs Æ Accessories Æ Communications Æ Hyper Terminal 2 Input connection name choose OK 3 Choose the correct COM port which connect to DTU choose OK 4 Configure the serial port parameters as following choose OK Bits per second 115200 Data ...

Page 21: ... XiaMen China 21 Zip Code 361008 Tel 86 592 6300320 86 592 6300321 86 592 6300322 Fax 86 592 5912735 http www four faith com www fourfaith com 5 Complete Hyper Terminal operation It runs as following 6 Re power DTU put mouse focus on the Hyper Terminal and press s key continuously until DTU enter configure state as following ...

Page 22: ...d J1 J2 3rd Floor No 44 GuanRi Road SoftWare Park XiaMen China 22 Zip Code 361008 Tel 86 592 6300320 86 592 6300321 86 592 6300322 Fax 86 592 5912735 http www four faith com www fourfaith com 7 DTU has entered configure state you can configure the parameters through AT command ...

Reviews: