Add
:
J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http
:
//www.fourfaith.com Tel
:
+86 592-6300326 6300325 6300324 Fax
:
+86 592-5912735
Note: Only there is some problem to the IP MODEM, It’s necessary to set this value as 2, In
normal applications, this value should set to 0 or 1, the default value is 1.
◆
Databit, Parity, Stopbit
8N1 --- 8 Databit, No parity, 1 Stopbit
8E1 --- 8 Databit, Even parity, 1 Stopbit
8O1 --- 8 Databit, Odd parity, 1 Stopbit
AT Command:
AT+SERMODE=xxx
xxx: one of the above serial mode
◆
Communication Baudrate
110 --- 110 bps
300 --- 300 bps
600 --- 600 bps
1200 --- 1200 bps
2400 --- 2400 bps
4800 --- 4800 bps
9600 --- 9600 bps
14400 --- 14400 bps
19200 --- 19200 bps
38400 --- 38400 bps
56000 --- 56000 bps
57600 --- 57600 bps
115200 --- 115200 bps
AT Command:
AT+IPR=xxx
xxx : one of the above baudrate