background image

                                                         

                              

User Manual                                                                                               

 

Xiamen Four-Faith Communication Technology Co.,Ltd.

 

                         

Page 38 of 46 

     

Add

   

J1-J3,3

rd

Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China

                                                                       

http

//www.fourfaith.com      Tel

  +86 592-6300326    6300325    6300324          Fax

+86 592-5912735

 

 

 

AT Command: 

 

          AT+EXCALx=SC,<afterTime> 

 

  <afterTime>: Countdown value(Unit:Second) 

 

For example: 

      IP Modem power off 600 seconds later: 

 

AT+EXCAL1=SC,60 

 

Note: If the <aftertime> is 0,the IP Modem will power off immediately. 

 

 

 

 

3.5.5 GPS Setting 

Settings on this page are the parameters of GPS function. 

Summary of Contents for F7114

Page 1: ...roduct Type F7114 GPS GPRS IP MODEM F7214 GPS CDMA IP MODEM F7314 GPS EDGE IP MODEM F7414 GPS WCDMA IP MODEM F7514 GPS TD SCDMA IP MODEM F7614 GPS EVDO IP MODEM Xiamen Four Faith Communication Technology Co Ltd Add J1 J3 3rd Floor No 44 GuanRi Road SoftWare Park XiaMen China Zip Code 361008 Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 http www fourfaith com ...

Page 2: ...nication Technology Co Ltd Page 2 of 46 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Files Revised Record Date Version Remark Author ...

Page 3: ...y Co Ltd Without written permission all commercial use of the files from Four Faith are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Four Faith 四信 are all registered trademarks of Xiamen Four Fait...

Page 4: ... Xiamen Four Faith Communication Technology Co Ltd Page 4 of 46 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 ...

Page 5: ...tions 8 Chapter 2 Installation Introduction 11 2 1 General 11 2 2 Encasement List 11 2 3 Installation and Cable Connection 11 2 4 Power 14 2 5 Indicator Lights Introduction 14 Chapter 3 Configuration 15 3 1 Configuration Connection 15 3 2 Configuration Introduction 15 3 3 Run the configure Tool IP Modem Configure exe 16 3 4 Re power IP MODEM 17 3 5 Configuration 17 3 5 1 Data Service Center Settin...

Page 6: ...sumption could be lower than 1mA 12VDC It has compatible digital I O channel ADC input pulse counter and pulse wave output function It has been widely used on M2M fields such as intelligent transportation smart grid industrial automation telemetry finance POS water supply environment protection post weather and so on 1 2 Features and Benefits Design for Industrial Application High powered industri...

Page 7: ...nt software for remote management Support several work modes Convenient configuration and maintenance interface High performance Support TCP server and support multi TCP client connection optional Support double data centers one main and another backup Supply 5 I O channels compatible 2 pulse wave output channels 2 analog inputs and one pulse input counters Support multi data centers and it can su...

Page 8: ...50MHz optional 153 6Kbps 30dBm 104 dBm F7314 GPS EDGE IP MODEM GSM850 900 1800 1900MHz GPRS EDGE Class 12 236 8Kbps GSM850 900 33dBm GSM1800 1900 30dBm 106 dBm F7414 GPS WCDMA HSDPA HSUPA IP MODEM UMTS WCDMA HSDPA HSUPA 850 1900 2100MHz 850 900 1900 2100MHz optional GSM850 900 1800 1900MHz GPRS EDGE CLASS 12 HSUPA 5 76Mbps Upload speed HSDPA 7 2Mbps Download speed UMTS 384Kbps DL UL 24dBm 109 dBm ...

Page 9: ... Aided Starts 1S Hot Starts Autonomous 1S Sensitivity Tracking Navigation 160dBm Reacquisition 160dBm Cold Start Autonomous 144dBm Timing Accuracy RMS 30ns 99 60ns Granularity 21ns Time Pulse Frequency Configurable 0 25Hz to 1000Hz Hardware System Item Content CPU Industrial 32 bits CPU FLASH 512KB Extendable SRAM 256KB Extendable Interface Type Item Content Serial 1 RS232 port and 1 RS485 orRS422...

Page 10: ...V Power Consumption Working States Power Consumption Communication 50 90mA 12VDC 115 165mA 5VDC Standby 25mA 12VDC 45mA 5VDC Sleep 8mA 12VDC 18mA 5VDC Timing Power Off 0 6mA 12VDC 1mA 5VDC Physical Characteristics Item Content Housing Iron providing IP30 protection Dimensions 91x58 5x22 mm Weight 210g Environmental Limits Item Content Operating Temperature 25 65º C 13 149 Extended Operating Temper...

Page 11: ...ter 2 Installation Introduction 2 1 General The IP MODEM must be installed correctly to make it work properly Warning Forbid to install the IP MODEM when powered 2 2 Encasement List Name Quantity Remark IP MODEM host 1 Cellular Antenna 1 GPS Antenna 1 Power adapter 1 RS232 data cable 1 optional RS485 data cable 1 optional Manual CD 1 Certification card 1 Maintenance card 1 2 3 Installation and Cab...

Page 12: ...to the SIM UIM card outlet Warning Forbid to install SIM UIM card when powered Installation of antenna Screw the SMA male pin of the cellular antenna to the female SMA interface of the IP MODEM with sign ANT Screw the SMA male pin of the GPS antenna to the female SMA interface of the IP MODEM with sign GPS Warning The cellular antenna and the GPS antenna can not be connected wrongly And the antenn...

Page 13: ... RI ADC and pulse output 12 IO5 GPIO Reserved compatible pulse wave input counter ADC and pulse output Installation of cable F7X14 adopts industrial terminal block interface The recommendatory cable is 28 16AWG The details description of standard layout adapter and communication cables is as following Adapter Rating Output 12VDC 0 5A Cable Color Power Output Polarity Black White Alternate Anode Bl...

Page 14: ...or Lights Introduction The IP MODEM provides three indicator lights Power ACT Online GPS Indicator Light State Introduction Power ON IP MODEM is powered on OFF IP MODEM is powered off ACT BLINK Data is communicating OFF No data Online ON IP MODEM has logged on network OFF IP MODEM hasn t logged on network GPS ON GPS data is communicating OFF No GPS data is communicating F7X14 Terminal Block Interf...

Page 15: ...ction There are two ways to configure the IP MODEM Configuration software tool All the settings are configured through the shipped software tool It s necessary to have one PC to run this tool Extended AT command All the settings are configured through AT command so any device with serial port can configure it Before configuration with extended AT command you should make IP MODEM enter configure st...

Page 16: ...al Parameters column shows the current serial port settings To configure IP MODEM please choose the correct serial port which connects to IP MODEM and the baud rate is 115200 with no parity then open the serial port If the button text is Close it shows the serial port now has been opened If the text is Open you should open the port first When the port opened the Output Info column will display Por...

Page 17: ...t configure columns It s now ready to configure 3 5 Configuration 3 5 1 Data Service Center Settings Settings on this page are the parameters related to Data Service Center DSC Data Center Number IP MODEM support two Data Service Center methods to transmit data Main and Backup IP MODEM always tries to connect with the Main DSC If fails to connect with Main DSC it will connect with Backup DSC at on...

Page 18: ...overned Setting details please reference the section 3 5 5 AT command AT SVRCNT x x Data Service Center number Note every AT command is terminated with a enter character Main Center Addr Port IP Address and Port of the Main DSC It s better to set the port greater than 1024 AT command of the Main DSC IP address or domain name AT IPAD xxx xxx The IP address or domain name AT command of the Main DSC ...

Page 19: ...domain name AT Command of the 2 5 DSC port AT PORTn xxx n is 1 4 correspond to port of center 2 5 xxx The port value Example Set IP address of center 3 as 166 111 8 238 and port 5001 the AT command is as following AT IPAD2 166 111 8 238 AT PORT2 5001 Main and Backup Center DNS Server When the DSC Internet access uses domain name It s necessary to set DNS server resolving the DSC domain name When t...

Page 20: ...quirements there are several protocol workmode to choose PROT Heartbeat packet with TCP protocol Data transmission with TCP protocol heartbeat packet and application data transmission are in the same TCP connection TRNS IP MODEM work as a common GPRS MODEM It can be used in SMS CSD Dial up applications TTRN Heartbeat packet with UDP protocol Data transmission with TCP protocol TLNT IP MODEM work a...

Page 21: ...into sleep state in idle time When there is application data to transmit IP MODEM can be triggered online ready for data transmission There are total five methods to make IP MODEM online AUTO IP MODEM always keeps online SMSD send a special short message to make IP MODEM online CTRL make IP MODEM online through a phone call to IP MODEM DATA send special serial data to make IP MODEM online MIXD the...

Page 22: ...l applications this value should set to 0 or 1 the default value is 1 Databit Parity Stopbit 8N1 8 Databit No parity 1 Stopbit 8E1 8 Databit Even parity 1 Stopbit 8O1 8 Databit Odd parity 1 Stopbit AT Command AT SERMODE xxx xxx one of the above serial mode Communication Baudrate 110 110 bps 300 300 bps 600 600 bps 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 bps 14400 14400 bps 19200 19200 ...

Page 23: ...witch to backup center when main center have problems If this item is set to 1 IP MODEM will check whether the main center work fine timely When it detects the main server work fine it will return back to the main server at once AT Command AT RETMAIN x x 0 or 1 Device ID The identity number of IP MODEM the value should be 8 bytes hex decimal characters AT Command AT IDNT aabbccdd aabbccdd the iden...

Page 24: ...time interval larger than this item value AT Command AT BYTEINT xxx xxx bytes interval time value millisecond Custom Register String This item is only valid when the WorkMode is TCST It s the self defined register string It can be empty the maximum length is 70 bytes AT Command AT CONNRGST xxx xxx self defined register string Custom Heartbeat String This item is only valid when the WorkMode is TCS...

Page 25: ...enter with the configured Retry Time It will sleep Reconnect Time Interval time then start next retry Connect Retry Times AT Command AT RETRY xxx xxx times try to connect to the center Reconnect Time Interval AT Command AT RDLWT xxx xxx the sleep time until next retry Transfer meanning 0 Yes enable transfer meaning 1 No disable transfer meaning This item is only valid when the WorkMode is PROT If ...

Page 26: ...ssword password to login the ISP network Call Center the call center phone number Model APN Username and password Call center F7114 Cmnet null 99 1 F7214 null card 777 F7314 cmnet null 99 1 F7414 3gnet null 99 F7514 cmnet null 98 1 F7614 null card 777 AT Command of APN AT APN xxxx xxxx access point name AT Command of Username AT USERNAME xxx xxx username AT Command of Password AT PASSWORD xxx xxx ...

Page 27: ...mmand AT POLLTIME xxx xxx heartbeat packet time interval Call Trigger Phone No This item is only valid when the Trigger Type is CTRL or MIXD In this trigger type IP MODEM will keeps in idle state until it receives the trigger phone call then it will connect to the center AT Command AT CTRLNO xxx xxx trigger phone number SMS Trigger Password This item is valid only when the Trigger Type is SMSD or ...

Page 28: ...ill return to the idle state when receives trigger off data AT Command of Data Trigger On Password AT DONPSWD xxx xxx data trigger on password AT Command of data trigger off password AT DOFFPSWD xxx xxx data trigger off password TCP MTU The maximum transmission unit of TCP packet AT Command AT TCPMTU xxx xxx the MTU value Multi Center Reconnect Interval This item is valid only when the Data Center...

Page 29: ...35 3 5 4 Scheduled Power ON OFF Setting RTC Real Time Clock Time Setting Click to ensure the setting AT Command AT EXCCLK yyyy mm dd HH MM SS W For example If the current time is at 12 30 on September 1st 2010 Wednesday the corresponding at command AT EXCCLK 2010 09 01 12 30 00 3 Power On Off Setting Press Set you will see the follow window you can do the setting AT Command AT EXCALx options value...

Page 30: ...n time S Shut Down Set the IP Modem power off time Setting type IP use for power on C use for power off T Time Set the action time point H per Hour Set a time point of every hour D per Day Set a time point of every day W per Week Set a time point of every week M per Month Set a time point of every month I Interval Set the time interval P Power always on C Count down Set the count down length 1 Dis...

Page 31: ...0324 Fax 86 592 5912735 AT Command AT EXCALx OT strLongTime holdTime strLongTime Format 2010 08 01 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 12 30 00 and power off at 13 30 00 on August 1st 2010 AT EXCAL5 OT 2010 08 01 12 30 00 3600 3 Power on per hour AT Command AT EXCALx OH strTime holdTime strTime Format 00 30 00 holdTime Hold time value Unit Second For exam...

Page 32: ... 6300326 6300325 6300324 Fax 86 592 5912735 IP Modem power on at the 30th minute in every hour and power off 10 minutes later AT EXCAL1 OH 00 30 00 600 4 Power on per day AT Command AT EXCALx OD strTime holdTime strTime Format 12 30 00 holdTime Hold on value Unit Second IP Modem power On at 09 00 00 everyday and power off 1 hour later AT EXCAL3 OD 09 00 00 3600 5 Power on per week ...

Page 33: ...y Thursday Friday and Sunday ordinal strTime Format 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 09 00 00 on every Wednesday and Friday and power off 1 hour later AT EXCAL1 OW 35 09 00 00 3600 The 35 replace to Wednesday and Friday 6 Power on per month AT Command AT EXCALx OM date strTime holdTime date 0 31 strTime Format 12 30 00 holdTime Hold time value Unit Sec...

Page 34: ...com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 7 Power on with time interval AT Command AT EXCALx OP intervalTime holdTime intervalTime interval time value Unit Minute holdTime Hold time value Unit Second For example IP Modem power on interval every 10 minutes and power off 120 seconds later AT EXCAL1 OP 10 120 8 IP Modem online offline with time interval ...

Page 35: ...el 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx OP intervalTime holdTime intervalTime interval time value Unit Minute holdTime Hold time value Unit Second For example IP Modem online interval every 10 minute and offline 120 seconds later AT EXCAL1 OP 10 120 Note IP Modem not power off in this mode it is standby 9 Power off at one time AT Command ...

Page 36: ...No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT EXCALx ST strTime 10 Power off per hour AT Command AT EXCALx SH strTime 11 Power off per day AT Command AT EXCALx SD strTime 12 Power off at the same time in every week ...

Page 37: ...6 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx SW week strTime 13 Power off per month AT Command AT EXCALx SM date strTime 14 Power off with countdown ...

Page 38: ...p www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 AT Command AT EXCALx SC afterTime afterTime Countdown value Unit Second For example IP Modem power off 600 seconds later AT EXCAL1 SC 60 Note If the aftertime is 0 the IP Modem will power off immediately 3 5 5 GPS Setting Settings on this page are the parameters of GPS function ...

Page 39: ...6300325 6300324 Fax 86 592 5912735 GPS data output interface There are two output interface and four modes for choosing 0 None No GPS data output 1 Network GPS data output via GPRS network 2 COM GPS data output via serial port 3 COM Network GPS data output via serial port GPRS network simultaneous AT Command AT GPSTRAN x x 0 None 1 Network 2 COM 3 COM Network GPS data output time interval ...

Page 40: ...data output time interval Note xxx should larger than 1 second and less than 65535 seconds GPS Data Service Center DSC Setting AT Command of GPS DSC IP address or domain name AT GPSAD xxx xxx The IP address or domain name AT Command of DSC port AT PORT xxx xxx The port value Note Please set the port value larger than 1024 GPS data transmit mode There are two modes for choosing TCP and UDP AT Comma...

Page 41: ...2 5912735 There are six items in the NEMA GPS data standard protocol such as GPRMC GPVTG GPGGA GPGSA GPGSV GPGLL The customer can enable or disable any of them AT Command AT FRMC x AT FVTG x AT FGGA x AT FGSA x AT FGSV x AT FGLL x x 0 Disable 1 Enable Note The default settings are all enabled 3 6 Functions Clear Output Clear the output information Version Display Show the software and hardware ver...

Page 42: ...tting Restore to factory settings Show Config Show current IP MODEM settings Show Baudrate Display the communication baudrate Auto Detect Simple way to determine whether IP MODEM work fine Save Output Save the output info to a file Save Config Save the current settings to a file you can restore it from this file later Restore Config Restore settings from a previous saved configure file 3 7 Work St...

Page 43: ...ina http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 This state is used to configure parameters of IP MODEM Communication This state is used as a common serial communication tool Reboot Device Enter Communication State This function button is used to reboot IP MODEM and make the software switch to Communication state ...

Page 44: ...325 6300324 Fax 86 592 5912735 Appendix The following steps describe how to make IP MODEM enter configure state with the Windows XP Hyper Terminal 1 Press Start Programs Accessories Communications Hyper Terminal 2 Input connection name choose OK 3 Choose the correct COM port which connect to IP MODEM choose OK 4 Configure the serial port parameters as following choose OK Bits per second 115200 ...

Page 45: ...361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 Data bits 8 Parity None Stop bits 1 Flow control None 5 Complete Hyper Terminal operation It runs as following 6 Re power IP MODEM put mouse focus on the Hyper Terminal and press s key continuously until IP MODEM enter configure state as following ...

Page 46: ... Ltd Page 46 of 46 Add J1 J3 3 rd Floor No 44 GuanRiRoad SoftWare Park XiaMen 361008 China http www fourfaith com Tel 86 592 6300326 6300325 6300324 Fax 86 592 5912735 7 IP MODEM has entered configure state you can configure the parameters through AT command ...

Reviews: