LIGHTING:

1. Remove the Access panel from the heater body exposing the gas regulator and the space for the 
propane cylinder.

2. Rotate the valve toward you, so that the attaching threads are visible. Thread the propane cylinder 
in place and ensure a tight seal.

3. Lower the propane cylinder into a vertical position and replace the panel.

4. Firmly press down on the control knob and turn left to the 9:00 o'clock position marked "ON". 
Release the knob.

5.  Hold the pilot control knob in and push the piezo button until the pilot 

fl

 ame appears. 

6. Continue holding the pilot control knob for up to one (1) minute before releasing. Pilot should 
remain lit.

7. Release Control Knob after 60 seconds. Pilot Light will remain lit. If not, return to Step 1.

8. If the pilot light does not come on, repeat Steps 4 and 5. NOTE: If a new tank has been put into 
service, allow the gas to replace the air in the line. This can take up to 10 seconds.

9. To start the burner, rotate the Control Knob in a clockwise direction and stop at the desired      
temperature position.

11

BEFORE TURNING GAS SUPPLY ON:

1. Your heater was designed and approved for outdoor use only. Do NOT use it inside a building, 
garage, or any other enclosed area.

2. Make sure surrounding areas are free of combustible materials, gasoline,and other flammable 
vapors or liquids.

3. Ensure that there is no obstruction to air ventilation.

4. Be sure all gas connections are tight and there are no leaks. 

5. Be sure the cylinder cover is clear of debris.

6. Be sure any component removed during assembly or servicing is replaced and fastened prior to 
starting.

BEFORE LIGHTING:

1. Heater should be thoroughly inspected before each use, and by a quali

fi

 ed service person at least 

annually.

2. If relighting a hot heater, always wait at least 5 minutes.

3. Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear. Suspected areas 
should be leak tested. If the hose leaks, it must be replaced prior to operation. Only use the 
replacement hose assembly speci

fi

 ed by manufacturer.

Summary of Contents for FM35PHLP

Page 1: ...tween 8 00 AM and 5 00 PM Eastern time Monday through Friday or email us at saleshelp sureheat com YOUR SAFETY 1 Read this Manual before attempting to assemble or operate your heater 2 Follow safety i...

Page 2: ...al Safety Instructions Components Hardware Assembly Process Gas Requirement Pre Operation Leak Testing Operation Care Maintenance Troubleshooting Warranty Table of Contents 3 5 6 7 8 8 10 11 12 13 14...

Page 3: ...sed extensively throughout this manual Always heed these precautions as they are essential when using any mechanical or fueled equipment RECOGNIZE SAFETY SYMBOLS WORDS AND LABELS WARNING indicates a p...

Page 4: ...lating air passageway of the appliance be kept clean FOR YOUR SAFETY If you smell gas 1 Shut off gas to the appliance 2 Extinguish open flame 3 If odor continues immediately call your gas supplier and...

Page 5: ...sed in compliance with local ordinances and codes or with ANSI NFPA 58 Turn off propane when not in use DANGER EXPLOSION FIRE HAZARD Never store propane near high heat open flames pilot lights direct...

Page 6: ...Reflector 3 Washer 4 Emitter 5 Wire guard 6 Access panel 7 Base 8 Cast iron ring weight 9 M6x20 bolts 4 pcs 10 3 16 Stainless bolts 4 pcs and washers 4 pcs 11 Post with burner assembly 12 3 16 Stainl...

Page 7: ...base using four bolts Step 1 Attach post onto housing using four bolts and washers Keep the access panel open Step 3 Attach emmitter assembly to post using four bolts and washers Step 4 Insert ends o...

Page 8: ...bolts then attach reflector to emitter assembly using three cap nuts Step 6 Rotate regulator toward opening in housing Line up threads on gas cylinder with those on the regulator Insert and rotate cyl...

Page 9: ...ust be constructed and marked in accordance with the specifications for L P gas cylinders of the U S Department of Transportation DOT or the National Standard of Canada CAN CAS B339 Cylinders Spheres...

Page 10: ...and repeat steps 1 3 3 Wash off soapy solution with cold water and towel dry Check all gas supply fittings before each use and each time the gas supply cylinder is connected to the regulator Have a qu...

Page 11: ...the air in the line This can take up to 10 seconds 9 To start the burner rotate the Control Knob in a clockwise direction and stop at the desired temperature position 11 BEFORE TURNING GAS SUPPLY ON 1...

Page 12: ...ff but the pilot light will remain on 2 To turn off the pilot light depress the control knob and rotate to the OFF position WARNING FOR YOUR SAFETY Heater will be hot after use Handle with extreme car...

Page 13: ...rous condition which can cause a fire to occur behind the valve panel thereby damaging the heater and making it unsafe to operate We recommend you check the heater and remove any spiders insects and w...

Page 14: ...t Clean dirt from around pilot Connection between gas valve and pilot assembly is loose Tighten connection and perform leak check Thermocouple is not operating correctly Replace thermocouple Burmer wo...

Page 15: ...uct to temperatures above its rated specifications which can cause considerable warping disassembly including removal of the product from a built in installation damage resulting from accident alterat...

Reviews: