59
4
3. HWM INfO. �Hardware Monitor Information�
Click "HWM INFO." button in the opening CONTROL PANEL to show the sensor's information.
Within this display, you can view the fan's speeds, temperatures and voltages.
Click on the rotating-fan button to control each fan function.
Fan control has 4 operating modes :
full Speed :
No control at all, running at full speed.
By Duty-Cycle :
The fan speed
is controlled by setting the percentage
to the fan duty (between 0% ~ 100%).
By Temperature:
The Temperature and Duty fields can be manually adjustable if you select them. The relationships
between temperature and duty field are defined as following
:
SEC1SPEED1 : If temperature is over 60°C, fan will be running at its 100% duty. (Range 100%)
SEC2SPEED1 : If temperature is over 50°C, fan will be running at 75% duty. (Range 75% ~ 99%)
SEC3SPEED1 : If temperature is over 30°C, fan will be running at 50% duty. (Range 50% ~ 74%)
SEC4SPEED1 : If temperature is over 20°C, fan will be running at 25% duty. (Range 25% ~ 49%)
If current temperature is below any level, fan will be
running at its lowest 20% duty.
By Smartfan:
Fan speed is controlled by the system automatically,
and user does not have to know about how it is
controlled.
Click to go to
Fan Control menu
Click to view HW
Monitor menu
Close this page