REPORT NO. :E930560
Page
14 of 31
NVLAP LAB CODE: 200097-0
-
PEP Testing Laboratory
12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih,
Taipei Hsien, Taiwan, R. O. C.
TEL: 886-2-26922097
FAX: 886-2-26956236
8.3 Radiated Emission Limits
Limits for radiated disturbance of Class
A ITE at
a measuring distance of 10 m
Frequency
MHz
Field Strength
dB(
Ӵ
V/m)
30 to 230
40
230 to 1 000
47
NOTES
1
The lower limit shall apply at the transition frequency.
2
Additional provisions may be required for cases where
interference occurs.
Limits for radiated disturbance of Class B ITE
at
a measuring distance of 10 m
Frequency
MHz
Field Strength
dB(
Ӵ
V/m)
30 to 230
30
230 to 1 000
37
NOTES
1
The lower limit shall apply at the transition frequency.
2
Additional provisions may be required for cases where
interference occurs.