THEA-130 / 160 Sprayer Drone
User Manual
©
2019 FOXTECH All Rights Reserved
7
If the throttle is not pushed to more than 10% after unlocking, the motor will automatically stop and lock after
3 seconds.
Immediately after the motor starts, release the rocker and take off as soon as possible.
If does not calibrate the range the remote control, the motor cannot be started by performing an unlock
operation.
If the fine adjustment of the joystick is not 0, the motor may not start when the unlocking operation is
performed!
Lock, Stop the Motor
The locking operation must be performed after the drone has landed. The motor can be stopped by
performing the following operations on the remote control.
Work in Manual Plus (AB point) Mode
When working in Manual mode and Manual Plus mode, you can use the ground station to view the track
and enter the viewing page of the ground station software.
Mode introduction
Manual Plus mode, also known as AB mode. After the user defines points A and B, the AB route is
automatically copied for flight. In the AB mode, it supports Terrain Following flight (with radar), supports
the adjustment of the length of the AB route during flight, and supports manual adjustment of altitude (the
middle position of the throttle defaults to a fixed altitude flight) and the direction of the nose.
Records AB Process in AB Mode
Takes off in the manual stabilization mode,if you do not want to use the AB point information of the previous
trip, you can continuously dial the G dial 7-8 times to clear the AB record to ensure that there is no AB point
inside the drone.
Operate the drone to the first starting point. In the manual stabilization mode, the G dial switch is switched
from standby to point A. At this point, the coordinates of point A are recorded. After the recording of point A
is successful, the LED light will flash with a purple light.
Manually open the water pump and control the drone to fly to the B point. In the manual stabilization mode,
the G dial switch switches from point A to point B and records the coordinates of point B. After the point B is
successfully recorded, there will be 2 purple lights flashing.
After the AB point recording is completed, the E dial switch is set to the AB mode, and then the roll channel
is switched to the far left or far right. At this time, the AB point mode starts to be executed, The aircraft will
continue to fly to the left/right ridge (the G dial switch is at position B, it is recommended to return to the
standby position).
Exit AB mode: E dial switches to manual stabilization mode/attitude mode to exit AB mode (the SB dial
switch is at position B, it is recommended to return to the standby position).
After exiting the AB mode, if you want to clear the AB point record, you need to continuously dial the G dial 7-8
times or more. At this time, the 2 flashing purple lights of the AB point will be extinguished, indicating that the
clearing is successful.
Lock