Integrated interfaces
47
6.17 Digital inputs 24 V
(Model series W550 and W667)
W550
W667
The digital inputs can be loaded with up to 24 V.
The status of the inputs can be queried with the following com-
mand.
W550
[<Get _="/Process/MB/IO/I/" ver="v"/>]
Answer (exemplary):
<Get>
<I>
<P0 _="0" />
<P1 _="0" />
</I>
</Get>
W667
[<Get _="/Process/C040/I/" ver="v"/>]
Answer (exemplary):
<Get>
<I>
<P0 _="0" />
<P1 _="0" />
<P2 _="1" />
<P3 _="0" />
<P4 _="1" />
</I>
</Get>
When not connected, the input shows a "1". If an input is con-
nected to earth, it shows a "0".
W550 key figures at a glance
– 2x digital inputs
– Module address:
MB/IO/I
– Name of connection terminal:
Dig.In
W667 key figures at a glance
– 5x digital inputs
– Module address:
C040
– Name of connection terminal:
M4.X