S4: Print Settings
S1: Imprint Offset
Steps:
Print Settings
Î
Print Offset
The print position is a standard 10mm from the right leading edge of the envelope. The image can be
moved a maximum of 99mm to the left.
S2: Resistance
Steps:
Print Settings
Î
Resistance
The resistance of the print head can be entered. Compared to the T1000 the high resolution head has a
higher resistance. The typical range is around 2k ohms
S5: Clock
S1: Time Zone
Steps:
S3: Settings
Î
Clock
Î
Time Zone
The system time is changed according to the local time zone that the meter is installed in.
S2: Summer time Changeover
Steps:
S3: Settings
Î
Clock
Î
Summer Time Changeover
The daylight savings can be turned on or off
S3: Calibrate Clock
Steps:
S3: Settings
Î
Clock
Î
Calibrate Clock
The clock can be calibrated once per week up to + or -300 seconds (5 minutes). The clock can only be
readjusted after 7 days has elapsed.
S6: Scale Settings
S1: Calibrate
Steps:
Scale Settings
Î
Calibrate
The internal scale can be calibrated.
To calibrate the scale follow the instructions in the display. During the calibration process make sure
that the scale is not touched and also that there are no vibrations.
10lb weight is required to calibrate the
internal scale
S2: Zero Adjust
Steps:
Scale Settings
Î
Zero Adjust
The current weight on the scale platform is zeroed.