background image

 

 
Part No.26117  Rev. F  September 2018 

- 18 - 

Inline 3000 Series Cabinets

 

 
 

 

Door Seals 

AMBIENT CABINETS 

 - 

SERVICING 

 
 

Seal 
Replacement 

The doors should be removed to allow the old seals to be removed and the new 
ones fitted.  See the Cleaning section for details. 

 

Sliding Doors 

Each sliding door has a seal between the door and the cabinet end panel.  The 
seal slides into a groove in the door extrusion, and can be withdrawn and 

replaced, if damaged. 
 
A centre seal is fitted 
between the inner and 
outer doors.  The Qlon 
seal is located in a slot 
in the aluminium 
extrusion, and can be 
replaced if damaged. 

 

 
Mains Lead 

AMBIENT CABINETS 

 - 

SERVICING 

 
 

Lead 
Replacement 

If damaged, the mains lead must ONLY be replaced by a qualified service 
person. 

 

 

Summary of Contents for IN 3A06

Page 1: ...Ambient Cabinets Curved Format...

Page 2: ...uture Products Group Limited All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopyin...

Page 3: ...ution 7 OPERATION 8 Cabinet Layout 8 3000 Series Cabinets 8 Lighting 8 Controls 8 Light Switch 8 Preparation 9 Shelf Location and Ticketing 9 Shelf Adjustment 9 Power Supply 9 Load Cabinet 9 Turn on L...

Page 4: ...tion 15 Location 15 Ventilation 15 Access 15 Fumes and Odours 15 Livery 16 Custom Inserts 16 SERVICING 17 Control Gear 17 Location 17 Lighting 17 Caution 17 Test Lighting Components 17 Access to LED S...

Page 5: ...S 21 Model IN 3A06 21 Model IN 3A08 21 Model IN 3A12 22 Model IN 3A15 22 SPARE PARTS 23 Cabinet Serial Number 23 MECHANICAL DRAWINGS 25 Dimensions 25 IN 3A06 25 IN 3A08 12 15 26 Cabinet Variants 27 Li...

Page 6: ...w its recommendations The time taken will be well spent These instructions both general and technical tell you how to install operate and look after your inline food service cabinet so that you can re...

Page 7: ...ge or malfunction resulting from the use of non FPG supplied spare parts Specific Exclusions The following are specifically excluded from warranty Breakage of glass or plastic components or the replac...

Page 8: ...d rear doors The series includes Ambient Heated and Refrigerated models The cabinet lighting controls are on the back of the cabinet Lighting All cabinets are fitted with high efficiency LED lighting...

Page 9: ...one on each bracket lift the brackets straight up firmly and then pull the brackets forward to disengage them from the slots in the support posts Insert the brackets into their new position and push b...

Page 10: ...eady for service turn on the cabinet lights Ventilation The cabinet is ventilated via louvers in the control panel above the rear doors If the louvers are blocked heat from the lights will raise the i...

Page 11: ...fuses on Internal fuse blown Have wiring checked and replace fuse 5A Slow Blow Cabinet Temperature High Ventilation louvers blocked Clean to remove blockage Extractor fan failed 600 only Replace fan C...

Page 12: ...el and aluminium surfaces will be damaged Glass All glass should be cleaned using a good quality glass cleaner and a clean cloth Do NOT clean glass with abrasive pads or cleaners e g Scotchbrite pads...

Page 13: ...sher detergents will damage any anodised aluminium parts Routines AMBIENT CABINETS CLEANING Schedules To maintain optimum performance cleaning schedules must be regular and thorough Inspection As part...

Page 14: ...r supplier The cabinet is supplied fully assembled but the shelf trays are packed separately Site Preparation Ensure the cabinet location and any bench cut outs are made to the precise measurements sh...

Page 15: ...the cabinet Isolation If the cabinet is not connected by a plug and socket but is hard wired to the mains supply a means of isolation must be provided If a plug and socket are used they should still b...

Page 16: ...ttom one The lower strip is held captive by the cabinet ends and has to be bowed for removal and insertion Insert the upper edge into the narrow groove closest to the curved surface bow the strip to i...

Page 17: ...D strip check that its power supply is working If there is no dc voltage at the output the power supply should be replaced If there is a dc output the LED strip must be replaced Access to LED Strips T...

Page 18: ...ors Each sliding door has a seal between the door and the cabinet end panel The seal slides into a groove in the door extrusion and can be withdrawn and replaced if damaged A centre seal is fitted bet...

Page 19: ...ack Single glazed Glass ends Double glazed Front Doors Sliding or Fixed options Number of Shelves Three plus base Display Area 0 7 m2 0 9 m2 1 4 m2 1 8 m2 Climatic Class IP Cabinets are tested under C...

Page 20: ...AS NZS CISPR and BS EN 55014 1 Essential safety requirements AS NZS 3820 and AS NZS 4417 Energy efficiency for refrigerated appliances MEPS Australia New Zealand Please contact FPG to discuss your re...

Page 21: ...IN 3A06 08 12 15 21 Future Products Group ELECTRICAL CIRCUIT DIAGRAMS Model IN 3A06 Inline 3000 Series 600mm Ambient Cabinet Model IN 3A08 Inline 3000 Series 800mm Ambient Cabinet...

Page 22: ...26117 Rev F September 2018 22 Inline 3000 Series Cabinets ELECTRICAL CIRCUIT DIAGRAMS Continued Model IN 3A12 Inline 3000 Series 1200mm Ambient Cabinet Model IN 3A15 Inline 3000 Series 1500mm Ambient...

Page 23: ...GO 14372 Knob light switch 14374 Fuse Link 5A 250V Slow Blow 13330 Ant surge Thermistor 10 Ohm 3A 22354 24V 60W LED power supply 21613 36V 100W LED power supply 25922 LED Driver 700mA 25762 Polycarbon...

Page 24: ...ng Door 1200 cabinets only 62664 Back Outer Sliding Door 1200 cabinets only 62665 Back Inner Sliding Door 1500 cabinets only 62666 Back Outer Sliding Door 1500 cabinets only 62667 Front Inner Curved S...

Page 25: ...IN 3A06 08 12 15 25 Future Products Group MECHANICAL DRAWINGS Dimensions AMBIENT CABINETS MECHANICAL DRAWINGS IN 3A06...

Page 26: ...Part No 26117 Rev F September 2018 26 Inline 3000 Series Cabinets Dimensions cont AMBIENT CABINETS MECHANICAL DRAWINGS IN 3A08 12 15...

Page 27: ...ANICAL DRAWINGS Cabinet Variants The drawings show the common overall dimensions for 800mm 1200mm and 1500mm cabinets The cabinets can have a single fixed front glass in place of the twin sliding door...

Page 28: ...ounting The following diagram shows the aperture dimensions which will allow the cabinet well to enter the bench The cabinet deck trays will then be just above bench height On Bench Mounting The follo...

Page 29: ...IN 3A06 08 12 15 29 Future Products Group...

Page 30: ...Part No 26117 Rev F September 2018 30 Inline 3000 Series Cabinets...

Page 31: ...IN 3A06 08 12 15 31 Future Products Group...

Page 32: ...to change specifications and design without notice AUSTRALIA E ausales fpgworld com T 1800 813 745 CHINA ASIA E asales fpgworld com T 86 21 3351 3390 EUROPE E eusales fpgworld com T 31 6 5253 4769 IND...