REFRIGERATED CABINETS
-
OPERATION
After Hours
Ideally, cabinets should not be turned off after hours or at night. Products can
either be left in the cabinet or placed in night storage. Shut the cabinet doors
and turn off the lights. The cabinet will then operate on minimum load, and stay
cold, ready for instant operation when next required.
If the cabinet is turned off, allow it to run for about half an hour before replacing
the pre-chilled products.
Cleaning
Since the cabinet needs to be switched off during cleaning operations, it is best
to clean it at the end of the working day. The cabinet will then have time to
recover its normal operating temperature, before replacing the products.
Once the cleaning is finished, turn the cabinet on again, turn off the lights and
shut the doors. The cabinet will cool down under minimum load and be ready
for the next day
’s use.
De-frost Cycle
The cabinet will de-frost automatically six times per day. The cabinet should
NOT be temperature tested within ½ hour of a de-frost programme being
completed.
The first defrost cycle will occur four hours after the cabinet is first switched on.
Door Opening
The cabinet is designed to maintain food at a temperature of 2
to 4
C. The
refrigeration system is designed to maintain this temperature with the doors
being opened and closed up to 60 times per hour.
If the doors are left open for an extended period the temperature will rise. Once
the doors are shut the temperature will take some time to fall to the normal
operating level. The longer the doors are open the longer the time to restore
normal operating temperature.
Summary of Contents for IN 3C06S
Page 1: ...Refrigerated Cabinets Square Format ...
Page 43: ...IN 3C06 09 12 15 SQ 43 Future Products Group IN 3C12S In counter mounting ...
Page 45: ...IN 3C06 09 12 15 SQ 45 Future Products Group IN 3C06S Counter top mounting ...
Page 47: ...IN 3C06 09 12 15 SQ 47 Future Products Group IN 3C12S Counter top mounting ...
Page 49: ...IN 3C06 09 12 15 SQ 49 Future Products Group IN 3C06S Free Standing ...
Page 50: ...Part No 26112 Rev H August 2018 50 Inline 3000 Square Series Cabinets IN 3C09S Free Standing ...
Page 51: ...IN 3C06 09 12 15 SQ 51 Future Products Group IN 3C12S Free Standing ...
Page 53: ...IN 3C06 09 12 15 SQ 53 Future Products Group ...
Page 54: ...Part No 26112 Rev H August 2018 54 Inline 3000 Square Series Cabinets ...
Page 55: ...IN 3C06 09 12 15 SQ 55 Future Products Group ...