IN 5A08/12/15/18
- 11 -
© Future Products Group
TROUBLE SHOOTING
FAULT
POSSIBLE CAUSE
REMEDY
Doors are not sliding smoothly
Door not in track
Install door correctly in track
Debris in track
Clean door tracks
(see cleaning)
Door glider damaged/missing
Have glider replaced
Lack of lubricant
Apply food grade lubricant to
door track
Cabinet lights not working
The mains isolating switch on
the wall, circuit breaker or
fuses are off at the power
board
Turn isolating switch circuit
breaker or fuses on
The light switch is OFF
Turn light switch ON
The light switch on the unit is
faulty
Have the switch replaced
A failed LED power supply
Replace the power supply
An LED strip has failed
Replace the LED assembly
Internal breaker tripped/failed
Have wiring checked and
reset or replace breaker
Cabinet Temperature High
Fan may have failed
Have fan checked/replaced
Aluminium parts corroded
Caustic detergent damage
Order replacement parts
Service
Personnel Only
The table entries in
italics
indicate actions to be taken only by qualified Service
Personnel.