IN 3H06/09/12/15
- 15 -
© Future Products Group
Setting Up
cont.
HEATED CABINETS - INSTALLATION
Grounding
WARNING: THIS APPLIANCE MUST BE GROUNDED TO EARTH
The grounding lead, in the mains cable, must always be connected to ground.
A binding post is also provided adjacent to the control gear chassis, to allow the
cabinet to be bonded to a surge grounding conductor or to adjacent equipment,
should this be required.
Power Supply
Before connecting to the power supply, check that the local supply is correct to
that shown on the rating plate, located on the rear of the cabinet.
Isolation
If the cabinet is not connected by a plug and socket, but is hard wired to the
mains supply, a means of isolation must be provided.
If a plug and socket are used, they should still be accessible after the cabinet is
installed.
Location
HEATED CABINETS
-
INSTALLATION
Ventilation
The heated cabinet is designed to meet the HACCP specification with free room
air circulation.
Access
Access to the back of the cabinet is required for loading, cleaning, re-positioning
of shelves and operation of the control panel.
Fumes and
Odours
Before use, operate the cabinet for 4 hours at 90°C, to remove any fumes or
odours, which may be present. Open the doors periodically during this period,
to allow a change of air. This will avoid possible tainting of food.