Part No.26113 Rev. G September 2018
- 16 -
Inline 3000 Square Series Cabinets
SERVICING
Control Gear
HEATED CABINETS
-
SERVICING
Location
The electrical control gear is located in the
top of the cabinet.
Remove the top plate to access the
control gear.
The chassis has a light switch, power
supplies for the lights and fan, a
thermostat, a thermometer, a ventilation
fan and a protective fuse.
Lighting
HEATED CABINETS
-
SERVICING
Caution
Do not service lights without isolating the cabinet from the mains supply.
Shelf Lights
Shelf lights are an optional extra, which can be fitted during manufacture.
Test Lighting
Components
Before replacing an LED strip, check that the power supply is working.
If there is no dc voltage at the output, the power supply should be replaced.
If there is a dc output, the LED strip must be replaced.
Access to LED
Strips
The LED strips are protected with
plastic covers. These clip into grooves
in the aluminium extrusion.
Remove the plastic cover to access the
LED strip.
The top light assembly is different from
the shelf lights, so the correct
replacement unit must be used.
Continued on next page