TROUBLE SHOOTING
Element Failure
Alarm Display
In the event of one or more infrared elements failing, the Dixell controller will display the
alarm
“EA”
along
with an audible alarm sound.
Turn the cabinet off and remove all food from the cabinet. Call for service.
FAULT
POSSIBLE CAUSE
REMEDY
Doors are not sliding smoothly
Door not in track
Install door correctly in track
Debris in track
Clean door tracks
(see cleaning)
Door glider damaged/missing
Have glider replaced
Lack of lubricant
Apply food grade lubricant to
door track
Cabinet does not operate/start
The mains isolating switch on
the wall, circuit breaker or
fuses are off at the power
board
Turn isolating switch circuit
breaker or fuses on
The power switch on the
cabinet is OFF
Turn the power switch ON
The power switch on the unit is
faulty
Have the switch replaced
Cabinet does not reach
temperature
One or more doors is open
Close doors and re-test
temperature after thirty
minutes
The Controller is faulty
Have controller replaced
The asymmetric timer
Have the timer replaced
A shelf or probe is unplugged
Check all plugs are inserted
An element fuse has blown
Check and replace fuse
An element is blown
Have the element replaced
Cabinet lights not working
An LED strip has failed
Replace LED assembly
An LED power supply failed
Replace power supply
An LED driver has failed
Replace LED driver
Internal breaker tripped/failed
Have wiring checked and
reset or replace breaker
Aluminium parts corroded
Caustic detergent damage
Order replacement parts
Service
Personnel Only
The table entries in
italics
indicate actions to be taken only by qualified
Service Personnel.
Summary of Contents for INLINE 5000C Series
Page 1: ...Heated Open front Cabinets Curved and Square Formats...
Page 28: ...Part No 27221 Rev G October 2019 28 5000 Series Open Front Cabinets IN 5H06 5H08 5H12 OF SQ...
Page 29: ...IN 5H06 08 12 OF 29 Future Products Group...
Page 30: ...Part No 27221 Rev G October 2019 30 5000 Series Open Front Cabinets...