background image

 

 

SAFETY WARNINGS

 

The product must only be installed by qualified persons, according to the local safety standards and regulations. Fracarro Radioindustrie is free from all civil and 
criminal responsibilities due to breaches of the current legislation derived from the improper use of the product by the installer, user or third parties. The product must 
be used in full compliance with the instructions given in this manual in order to protect the operator against all possible injuries and the product from being damaged. 
Never remove the lid of the product as there are live parts inside.

 

INSTALLATION WARNINGS

 

 

The product must not be exposed to any dripping or splashing and thus it should be installed indoors and in a dry location. 

 

Humidity and condensation could damage the product. In case of condensation, wait until the product is dry before using it. 

 

Handle the product carefully. Impacts can damage the product.  
Leave enough space around the product to ensure sufficient ventilation.  

 

Excessive temperatures and/or an overheating may affect the performance and the life of the product. 

 

Don’t install the product above or near any heat sources, in dusty places or where it might come into contact with corrosive substances. 

 

In the event that the unit is fixed to the wall, use the proper screw anchors suitable to the characteristics of the fixing support. The wall and the anchoring 
system must be able to support at least 4 times the weight of the unit. 

 

Warning: to avoid injury, this appliance must be secured to the wall / floor depending on the installation instructions. 

 

For "PERMANENTLY INSTALLED APPLIANCES", an easily accessible cutting device must be added to the exterior of the appliance; for "APPLIANCES 
WITH A POWER PLUG", the socket must be installed close to the appliance and easily accessible. 

 

The product must be connected to the grounding electrode of the antenna system in compliance with standard EN 60728-11. The screw provided for this 

purpose is marked with the symbol 

 

We recommend that you comply with the provisions of standard EN 60728-11 and do not connect this screw to the Protective Earth of the electricity supply.  

 

    Class II symbol 

 Earth screw/Faston connector symbol 

GENERAL WARNINGS

 

In the event of a malfunctioning, do not try to fix the product as the guarantee would be invalidated. Only use the power supply supplied with the product. 
Although the information given in this manual has been prepared carefully and thoughtfully, Fracarro Radioindustrie S.r.l. reserves the right to modify it without 
notice and to improve and/or modify the product described in this manual. See the website 

www.fracarro.com

 to have information relevant to the technical support 

and product guarantee.

 

 

CONFORMITY WITH EUROPEAN DIRECTIVES

 

Fracarro  declares  that  the  product  complies  with  EU  Directive  2014/30/UE,  2014/35/UE  and  2011/65/UE.  The  full  text  of  the  EU  Declaration  of  Conformity  is 
available on the following website: 

ce.fracarro.com

 

USER’S INFORMATION 

Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection system) 

    

 

 

This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed 
over  to  the  applicable  collection  point  for  the  recycling  of  electrical  and  electronic  equipment.  By  ensuring  this  product  is  disposed  of 
correctly, you will help prevent potential negative consequences for the environment and human health, wich could otherwise be caused by 
inappropriate  waste  handling  of  this  product.  The  recycling  of  materials  will  help  to  conserve  natural  resources.  For  more  detailed 
information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where 
you purchased the product. 

 

 

Equipment intended for indoor usage only. 

 
Fracarro Radioindustrie decline every responsability for improper use of the device or for the 
unauthorized distribution of sensitive content trough the coaxial distribution. 
 

Contact Information 

Fracarro Radioindustrie SRL 

Via Cazzaro n.3 - 31033 Castelfranco Veneto (TV) - ITALIA - Tel: +39 0423 7361 - Fax: +39 0423 736220  

www.fracarro.com

   

 

 

 

 

 

Email: 

supportotecnico@fracarro.com 

 

chat whatsapp

 +39 335 7762667 

 
 

Fracarro France S.A.S. 

7/14 rue du Fossé Blanc Bâtiment C1 - 92622 Gennevilliers Cedex - FRANCE Tel: +33 1 47283400 - Fax: +33 1 47283421 

Fracarro (UK) - Ltd  

Unit A, Ibex House, Keller Close, Kiln Farm, Milton Keynes MK11 3LL UK - Tel: +44(0)1908 571571 - Fax: +44(0)1908 571570 

 

 

Summary of Contents for FRPRO EVO HD

Page 1: ...ect the device to the grounding electrode of the antenna system and fix the FRPRO EVO HD in vertical position for guarantee the correct ventilation and heat dissipation Connect the power cord to the power supply socket Check the status LED for DC power presence Connect the VHF UHF and or FM aerial s coaxial cables to the FRPRO EVO HD Connect the RF output coaxial cable to the RF coaxial distributi...

Page 2: ...firm button for two seconds to access the different menù or for confirm the selection Scroll all the menu by using left down or right up arrows for move through the different menù Input settings Select INPUT FM to setup the desired FM input signal gain Select INPUT 1 4 to enter the VHF UHF input settings NOTE the first TV channel selected determine if the INPUT becames a VHF or UHF input only Turn...

Page 3: ...VHF UHF 1x FM Frequency range MHz FM 88 108 VHF 174 240 UHF 470 862 Input level dBμV FM 37 77 VHF 40 109 UHF 40 109 LTE Protection MHz Automatic selection 694 790 or disabled RF Output Ouput power dBμV FM 113 60dB IM3 VHF UHF 120 60dB IM3 VHF UHF 113 for 1 MUX VHF UHF 110 for 6 MUX Gain Adjustment dB FM 35 20 VHF 45 auto AGC UHF 55 auto AGC Output total adjustment dB 20 Output total slope adjustme...

Page 4: ...Earth screw Faston connector symbol GENERAL WARNINGS In the event of a malfunctioning do not try to fix the product as the guarantee would be invalidated Only use the power supply supplied with the product Although the information given in this manual has been prepared carefully and thoughtfully Fracarro Radioindustrie S r l reserves the right to modify it without notice and to improve and or modi...

Page 5: ...zionabile per tutti gli ingressi VHF UHF Istruzioni rapide per l installazione Collegare il dispositivo al sistema di messa a terra dell impianto d antenna e fissare la centrale FRPRO EVO HD in posizione verticale per garantire la corretta ventilazione e dissipazione del calore Collegare il cordone di alimentazione alla presa elettrica Verificare la presenza dell alimentazione mediante il led STAT...

Page 6: ...ale FRPRO EVO HD può essere effettuata utilizzando il display e i tre pulsanti disponibili sulla parte superiore vedere Schema sopra riportato Per accedere ai differenti menù premere il pulsante conferma per due secondi Lo stesso pulsante si utilizza anche per confermare le varie selezioni Per muoversi all interno dei vari menù si utilizzano i pulsanti sinistra basso oppure destra alto Programmazi...

Page 7: ...FRPRO EVO HD completo dalla sezione prodotti nel sito www fracarro it FRPRO EVO HD Codice Fracarro 287434 Ingresso N ingressi N 4x VHF UHF 1x FM Range di frequenza MHz FM 88 108 VHF 174 240 UHF 470 862 Livello di ingresso dBμV FM 37 77 VHF 40 109 UHF 40 109 Protezione LTE MHz Selezione Automatica 694 790 o disabilitato RF Output Livello di uscita dBμV FM 113 60dB IM3 VHF UHF 120 60dB IM3 VHF UHF 1...

Page 8: ... collegare tale vite alla terra di protezione della rete elettrica di alimentazione Simbolo di classe II Simbolo di terra dell impianto d antenna AVVERTENZE GENERALI In caso di guasto non tentate di riparare il prodotto altrimenti la garanzia non sarà più valida Utilizzare esclusivamente l alimentatore fornito in dotazione con il prodotto Le informazioni riportate in questo manuale sono state comp...

Page 9: ...électionnable pour toutes les entrées VHF UHF Instructions pour l installation Branchez la station à la mise à la terre de l installation d antenne et fixez la en position verticale pour garantir une bonne ventilation et dissipation de la chaleur Branchez le cordon d alimentation à la prise électrique et vérifiez que la led STATUS soit allumée Branchez lzs câbles coaxiax des antennes VHF UHF et FM...

Page 10: ... régler le gain de l entrée FM Sélectionnez INPUT 1 4 pour entrer dans le menu des entrées VHF UHF NOTA le premier canal sélectionné définit le type d entrée VHF ou UHF Si le niveau d entrée est trop faible paramétrez sur ON la section PRE AMPLI de manière à activer l étage de pré amplification Si vous utilisez des pré amplis de mât activez la télé alimentation ON dans la section DC le courant max...

Page 11: ...F UHF 1x FM Gamme de fréquences d entrée MHz FM 88 108 VHF 174 240 UHF 470 862 Niveau d entrée dBμV FM 37 77 VHF 40 109 UHF 40 109 Protection LTE MHz Sélection automatique 694 790 ou désactivé Sortie RF Niveau de sortie dBμV FM 113 60dB IM3 VHF UHF 120 60dB IM3 VHF UHF 113 pour 1 MUX VHF UHF 110 pour 6 MUX Gain Réglage dB FM 35 20 VHF 45 auto AGC UHF 55 auto AGC Réglage générald de sortie dB 20 Ré...

Page 12: ... l installateur de l utilisateur ou de tirces personnes L installation du produit doit être réalisée suivant la notice fournie pour éviter d éventuels accidents à l installateur et l éventuel endommagement du produit N ôtez jamais le couvercle de l alimentation car des parties sous tension dangereuse sont accessibles à l ouverture du boîtier INSTRUCTIONS POUR L INSTALLATION Le produit doit être in...

Reviews: